Panasonic air conditioners store a fault code you retrieve with the remote's CHECK button — the blinking TIMER light only tells you a code exists. Codes come in two families: H-codes (sensors, communication, components) and F-codes (refrigeration cycle and compressor protection). The tables below cover the residential wall split, Free Multi and compact ducted ranges.

Before you scroll: exact meanings can vary between model series — treat this as a well-informed starting point, not a service manual for your specific unit. And if a code appears alongside burning smells, breaker trips or water pouring from the unit, skip the table: switch off and call 0434 951 341.

How to find your Panasonic fault code

1

Wall splits — read the code back through the remote

  1. 1 Panasonic doesn't use flash counting: a blinking TIMER light only means a code is stored. You retrieve it with the remote.
  2. 2 Press the recessed CHECK button (a pin-hole under the slide-down cover) and hold for 5 seconds — the display changes to “- -”.
  3. 3 Press the TIMER up/down button to step through codes, starting at H00.
  4. 4 When the displayed code matches the stored fault, the unit's POWER lamp lights for 30 seconds and you get a continuous ~4-second beep. That code on screen is your fault. (Short flash, no beep = not a match.)
  5. 5 Hold CHECK for 5 seconds to exit — or it exits itself after 30 seconds. Wi-Fi models also show the code in the Comfort Cloud app.
2

Wired controllers (ducted and cassettes)

  1. 1 No beep method needed — the code flashes directly on the controller screen, with the indoor unit number on multi/group systems.
  2. 2 Note the whole code (letter plus digits) before switching anything off.
  3. 3 Alarm history lives in the controller's maintenance menu — normally a technician function.
Worth knowing: This H/F table covers Panasonic's residential inverter family (wall splits, Free Multi and compact residential ducted). Ducted systems built on the commercial PACi platform can raise codes in other letter families (E-, P- and L-codes), and a handful of H/F codes shift meaning between generations — confirm against the manual for your exact model number, or quote the model and code to Panasonic Australia on 132 600.

Panasonic fault code tables

Try this first safe check before calling anyone Book a service needs a technician Switch off & call stop running the system

Communication and installation faults (indoor-outdoor)

Code What it means Likely cause What to do
H00 No abnormality detected - the unit has no fault stored in memory Shown during remote-control self-diagnosis when no error has been logged; the problem may be intermittent or not fault-related (e.g. power supply, remote batteries) Try this first
H11 Indoor/outdoor communication failure - the head unit and outdoor unit have stopped talking to each other (detected about 1 minute after start-up; unit may run fan-only) Loose or damaged interconnect cable between indoor and outdoor units, or a faulty indoor/outdoor PCB; occasionally a transient after a power interruption Try this first

Switch the system off at the isolator or breaker for 2 minutes, then restore power and retest - if H11 returns, book a technician (wiring/PCB diagnosis is not DIY)

H12 Multi-split capacity mismatch - the total capacity of connected indoor units is outside the outdoor unit's allowed range (checked ~90 seconds after power-up) Wrong indoor/outdoor combination, too many or too few indoor units connected, or crossed interconnect wiring on a multi-split Book a service
H33 Indoor/outdoor misconnection - units with different rated voltages have been connected together Mismatched indoor and outdoor units or incorrect interconnect wiring at installation Book a service
H38 Indoor/outdoor brand-code mismatch - the units do not recognise each other as a matched pair Indoor and outdoor units from incompatible ranges paired together, usually after a partial replacement Book a service
H39 Abnormal indoor operating unit or standby unit (multi-split systems) - a standby indoor unit is freezing or misbehaving while another runs Refrigerant pipes and inter-unit wiring crossed between rooms at installation, or a faulty expansion/solenoid valve on the outdoor unit serving that room Book a service
H41 Wrong wiring or piping connection detected on a multi-split system Interconnect wires and refrigerant pipes crossed between rooms at installation, or an expansion-valve fault Book a service

Temperature and pressure sensor faults

Code What it means Likely cause What to do
H14 Indoor intake air (room temperature) sensor fault Sensor open-circuit or short-circuit, or a loose lead/connector on the indoor unit Book a service
H15 Compressor temperature sensor fault Sensor open-circuit or short-circuit, or a loose lead/connector at the outdoor unit Book a service
H16 Outdoor current transformer (CT) abnormality - the outdoor unit is drawing abnormally low current Insufficient refrigerant (gas leak), a faulty CT circuit on the outdoor PCB, or a failing power module/compressor Book a service
H17 Outdoor suction pipe temperature sensor fault (open or short circuit) Defective or disconnected suction/intake pipe sensor on the outdoor unit, corroded connector, or damaged sensor wiring Book a service
H23 Indoor heat exchanger (pipe) temperature sensor 1 fault Sensor open-circuit or short-circuit, or a loose lead/connector Book a service
H24 Indoor heat exchanger temperature sensor 2 fault Sensor open-circuit or short-circuit, or a loose lead/connector Book a service
H27 Outdoor (ambient) air temperature sensor fault Sensor open-circuit or short-circuit, or a loose lead/connector on the outdoor unit Book a service
H28 Outdoor heat exchanger temperature sensor 1 fault Sensor open-circuit or short-circuit, or a loose lead/connector Book a service
H30 Outdoor discharge pipe temperature sensor fault Sensor open-circuit or short-circuit, or a loose lead/connector Book a service
H32 Outdoor heat exchanger temperature sensor 2 fault Sensor open-circuit or short-circuit, or a loose lead/connector Book a service
H34 Outdoor heat-sink temperature sensor fault (power module cooling sensor) Sensor open-circuit or short-circuit on the outdoor control board Book a service
H36 Outdoor gas pipe temperature sensor fault Sensor open-circuit or short-circuit, or a loose lead/connector Book a service
H37 Outdoor liquid pipe temperature sensor fault Sensor open-circuit or short-circuit, or a loose lead/connector Book a service
H59 ECONAVI (human activity/sunlight) sensor fault, detected for 25 seconds continuously ECONAVI sensor open/short circuit, disconnected, or a faulty ECONAVI PCB - the unit usually still cools/heats with ECONAVI off Book a service
H64 Outdoor high-pressure sensor fault (detected while the compressor is stopped) High-pressure sensor open-circuit, loose lead/connector, or PCB fault Book a service
H70 ECONAVI light/human-detection sensor abnormality Light sensor open or short circuit, or feedback signal stuck (detected continuously over an extended period); unit usually keeps cooling but ECONAVI features stop working Book a service

Fan motors, drainage and accessory faults

Code What it means Likely cause What to do
H19 Indoor fan motor locked or feedback abnormal - the indoor fan cannot spin properly Jammed or obstructed fan barrel, failed fan motor, or a loose motor lead/connector Book a service
H21 Condensate drain fault - float switch has tripped (models with a drain pump, e.g. ducted and cassette units) Blocked drain line or drain pan, failed drain pump, or a defective float sensor Try this first

Check the condensate drain outlet is not blocked or kinked and that water can run away freely; if the code returns after a 2-minute power cycle, book a technician

H25 e-ion / ionizer unit fault (older models with air-purifying ion generator) Defective ion unit or indoor PCB - normal cooling/heating usually continues Book a service
H26 Ionizer (minus-ion) fault on older air-purifying models Defective ion generator or indoor board Book a service
H50 Ventilation/fan motor or its control board defective (model-dependent) Failed fan motor or indoor PCB Book a service
H51 Nozzle lock / nozzle blockage abnormality (automatic filter-cleaning mechanism) The self-clean robot nozzle is jammed or blocked by dust build-up; judged after 2 consecutive occurrences. Applies to models with automatic filter cleaning Book a service
H52 Limit switch abnormality (filter-cleaning mechanism cannot detect its end position) Faulty left/right limit switch on the automatic filter-cleaning unit or a fault on the indoor PCB Book a service
H67 nanoe / nanoe X abnormality — the air-purifying module has stopped for 5 minutes on three occasions. Faulty nanoe device, its high-voltage supply or the PCB. (On Panasonic Aquarea heat pumps H67 means something different — this table is for air conditioners.) Book a service
H85 Communication fault between the indoor unit and the built-in wireless LAN (Wi-Fi) module Network adaptor fault, router problem or poor Wi-Fi coverage - air conditioning itself keeps working Try this first

Restart your Wi-Fi router and power-cycle the air conditioner at the breaker for 2 minutes; re-pair in the Comfort Cloud app - only book service if the code persists with a healthy network

H97 Outdoor fan motor locked or feedback abnormal (detected twice within 30 minutes) Debris, leaves or ice jamming the outdoor fan, a failed fan motor, or a loose lead/connector Try this first

With the unit switched off at the breaker, clear leaves, debris and vegetation from around the outdoor unit and check nothing is fouling the fan, then power-cycle - book service if it recurs

Protection trips (airflow-related, often DIY-recoverable)

Code What it means Likely cause What to do
F17 Multi-split standby indoor unit freezing - an indoor unit that was idle has started to ice up Crossed pipe/wiring connections on a multi-split, a leaking expansion valve, or a heat-exchanger sensor fault Book a service
F95 Outdoor high-pressure protection in cooling - the outdoor coil is running too hot (tripped 4 times within 20 minutes) Blocked or filthy outdoor coil, debris/vegetation choking airflow, outdoor fan problem, or a refrigeration-circuit fault Try this first

Switch off and clear debris, plants and obstructions from all sides of the outdoor unit so air can flow freely, then power-cycle - if F95 returns, book a technician

H98 Indoor high-pressure protection in heating mode - the unit throttled or stopped itself to prevent overheating (often stored in memory without an alarm) Dirty air filters, blocked indoor airflow (short-circuiting), furniture/curtains obstructing the unit, or a dirty indoor coil Try this first

Clean the air filters and make sure nothing blocks the indoor unit's intake and outlet, then power-cycle for 2 minutes - if it keeps tripping, book a service (the coil may need professional cleaning)

H99 Indoor freeze protection in cooling mode - the indoor coil started icing up so the unit protected itself Dirty filters or restricted airflow over the indoor coil; if it persists after cleaning, low refrigerant is likely Try this first

Clean the filters, let any ice fully thaw with the unit off, then restart - if H99 recurs with clean filters, book a technician to check refrigerant charge

Refrigeration cycle, compressor and electrical faults (F codes - do not keep running the unit)

Code What it means Likely cause What to do
F11 4-way (reversing) valve switching failure - the unit cannot change over between heating and cooling correctly (4 trips within 30 minutes) Stuck or failed reversing valve, or its solenoid coil/lead Book a service
F90 Power factor correction (PFC) circuit protection on the outdoor inverter board (4 trips within 10 minutes) Faulty outdoor inverter PCB or abnormal power input; sometimes compressor winding issues Switch off & call
F91 Refrigeration cycle abnormality - the system detects it is not moving heat properly (2 trips within 20 minutes) Insufficient refrigerant from a gas leak, or a service valve left closed/partially closed Switch off & call
F93 Compressor abnormal revolution - the compressor is not rotating as commanded Failing power transistor (inverter) module, compressor winding fault, or a locked/seizing compressor Switch off & call
F94 Compressor discharge pressure overshoot protection (4 trips within 30 minutes) Overpressure in the refrigeration circuit - overcharge, blockage or a system fault Switch off & call
F96 Power transistor module (IPM) overheating protection (4 trips within 30 minutes) Overheated inverter power module - failing module, poor heat-sink contact, or restricted outdoor airflow Switch off & call
F97 Compressor overheating protection - discharge temperature too high (3 trips within 30 minutes) Insufficient refrigerant (leak) or a refrigeration-circuit fault causing the compressor to run hot Switch off & call
F98 Total running current protection - the system is drawing too much power (3 trips within 20 minutes) Overcurrent from a refrigeration-system problem, power-supply issue, or a compressor beginning to lock Switch off & call
F99 Outdoor DC peak current detection - the inverter cut out on an instantaneous current spike (7 consecutive detections) Failed power transistor module, compressor winding short, or a locked compressor Switch off & call

Reference compiled from Panasonic service and operation documentation. Codes and meanings are provided as general guidance for the Australian residential range and can differ between model series; no affiliation with Panasonic is implied.

Found your code?

Tell us the code when you book — diagnosis starts before we arrive

Air conditioning service and repairs across Perth from $220 inc GST — all brands, splits and ducted. Quoting the fault code gives us a head start on where to look; we then test and confirm the actual fault on site before any part is ordered, so you never pay for a part you didn't need.

Frequently Asked Questions

How do I get the error code out of my Panasonic?

Hold the recessed CHECK button on the remote (a pin-hole under the slide-down cover) for 5 seconds until the display shows “- -”, then press TIMER up/down to step through codes. When the code matches the stored fault, the unit beeps for about 4 seconds and the POWER lamp lights for 30 seconds — that's your code. Full steps are above the tables.

What does H00 mean?

No fault stored — the diagnostic ran and found nothing in memory. If the unit is misbehaving but reports H00, the problem is more likely airflow, settings or sizing than an electronic fault.

What's the difference between H codes and F codes?

Broadly, H-codes cover sensors, communication, fan motors and accessories, while F-codes cover the refrigeration cycle, compressor and inverter protection. F-codes more often mean stop-using-it-and-call; H-codes more often have a simple cause like a blocked filter or a loose connector.

My Wi-Fi Panasonic shows the code in the app — is that the same code?

Yes. Newer Wi-Fi models push the same H/F code to the Comfort Cloud app, which saves the remote button sequence entirely. Look it up in the tables here the same way.

Rated 5.0 from 20 Google reviews

Perth homeowners have trusted us for 10+ years. Here's what they say.

Real five-star reviews from Perth homeowners — see why locals choose Otter Air for air conditioning and electrical work.

See all reviews

“Phenomenal service provided by Matt! The works was done on schedule and to a professional standard. The price was also very reasonable for the works done. I highly recommend for anyone looking to get aircon work done, and I wish Otter Air Conditioning the best for their future endeavours.”