9kW of cooling and 10.3kW of heating make the FTXV90 a whole-zone climate system that happens to hang on a wall. It's the practical alternative when ducted isn't an option — no roof space, no zoning complexity, one big room done properly. Exact price confirmed at a free site visit.
Sized right, 9kW comfortably covers around 60 m² in Perth conditions — large open-plan living/kitchen. In quiet mode the indoor unit drops to 38 dB(A). If you're between sizes, we'll tell you straight at the quote which way to go — an undersized unit runs flat-out and wears early, an oversized one short-cycles.
Daikin's large-capacity wall splits — 8kW to 9.5kW from a single indoor unit. These are the answer when one big open-plan space needs serious cooling but ducted is overkill or the roof space won't allow it. Big singles are more involved than a standard split: the dedicated circuit, wall position and airflow throw all need to be right, so the from-price assumes a straightforward install and we confirm the exact figure at a free site visit.
How pricing works
Why the Daikin 9kW is quoted on site
At 9kW the electrical load, wall position and airflow throw matter more than on a standard split, so a flat rate would either overcharge easy jobs or underquote hard ones. We measure up at a free site visit and give you one fixed price covering the unit, the install and all electrical. A standard install covers:
- The indoor head and outdoor unit, mounted, levelled, and secured
- Up to 3 metres of insulated refrigerant pipework in neat trunking
- Electrical connection to a suitable existing circuit, with an isolating switch at the outdoor unit
- Condensate drain run to ground level
- Standard outdoor mounting (blocks at ground level, or a wall bracket where specified)
- Vacuum, pressure test, and refrigerant charge to the manufacturer's spec
- Full run test, commissioning, remote demo, and the compliance paperwork
What lifts a quote above the from-price: long pipe runs, two-storey or high mounting, tricky access, and the dedicated circuit this size requires (which we run in-house — no second electrician). The full breakdown is in our Perth split system cost guide, or get a number for your wall with the cost calculator.
The Daikin Large-Capacity range
Why we fit the Daikin Large-Capacity
Large open-plan living/kitchen zones, big rumpus rooms, and homes where ducted isn't practical.
Serious single-unit capacity
Up to 9.5kW of cooling from one wall unit — enough for 60m²+ of open-plan space in Perth conditions.
One unit instead of two
A single big split often beats two mid-size units on install cost, wall space, and having one system to maintain.
Reverse-cycle heating to match
Up to 10.3kW of heating capacity — a genuine whole-zone heater for Perth winters.
Sized and priced properly
Big-capacity installs vary more than standard splits — dedicated circuit sizing and placement matter — so the from-price is a straightforward install and the exact figure is confirmed at a free site visit.
Specifications
Daikin 9kW specifications
| Indoor unit | FTXV90WVMA |
| Outdoor unit | RXV90WVMA |
| Cooling capacity | 9kW (range 2–11.2kW) |
| Heating capacity | 10.3kW (range 1.9–12kW) |
| EER (cooling efficiency) | 3.4 |
| COP (heating efficiency) | 3.27 |
| Energy stars (hot zone — Perth) | 3★ cooling · 2.5★ heating |
| Indoor sound (high / quiet) | 53 / 38 dB(A) |
| Outdoor sound (high / quiet) | 54 / 51 dB(A) |
| Refrigerant | R32 |
ZERL hot/avg/cold — cooling 3/3/3, heating 2.5/2/1.5. Rated to AS/NZS 3823. Specs from manufacturer literature — always confirmed at quote.
Other Daikin Large-Capacity sizes
Daikin 9kW — common questions
How much does the Daikin 9kW cost installed in Perth?
Large-capacity installs are quoted individually — circuit sizing, wall position and airflow throw vary too much for a fair flat rate. We'll give you a fixed, all-in price at a free site visit, usually within 24 hours of seeing the space.
What size room does the Daikin 9kW suit?
As a Perth rule of thumb, 9kW of cooling comfortably handles a room of around 60 m² — large open-plan living/kitchen. Ceiling height, insulation, and big west-facing windows shift the answer, which is why we always confirm sizing at the quote.
Does the Daikin 9kW need its own electrical circuit?
Yes — anything above 3.5kW needs a dedicated circuit from the switchboard. Because we're dual-licensed in air conditioning and electrical, the circuit, isolator and any switchboard work are part of the same quote and the same visit — no second tradie.
What warranty does the Daikin 9kW come with?
Daikin 5-year parts and labour warranty, plus our own workmanship warranty on the installation. Installation by an ARC-licensed tech and a licensed electrician — the same team, on the same job — protects your manufacturer warranty; an unlicensed install is the usual reason a claim gets knocked back.
Perth homeowners have trusted us for 10+ years. Here's what they say.
Real five-star reviews from Perth homeowners — see why locals choose Otter Air for air conditioning and electrical work.
See all reviewsDaikin 9kW, quoted for your home
One licensed local team for the whole job — the unit, the install, and the electrical. Free quote, fixed price, no surprises on the day.