Perth's Mitsubishi Electric fault code lookup

Mitsubishi Electric fault codes decoded

79 codes covered — what each one means, the likely cause, and whether it's worth trying something yourself before booking. Compiled from Mitsubishi Electric documentation.

FAST RESPONSE
Prompt & reliable
FREE QUOTES
No obligation
WA OWNED
Local family team
FULLY INSURED
Licensed & covered

Mitsubishi Electric systems report faults three ways: as blink counts on the indoor unit's operation indicator (MSZ wall splits), as two-character check codes on wired controllers (P, E, U and F codes), and as 4-digit codes on newer PAR-40/41 controllers and MELCloud. All are covered below for the residential MSZ, MXZ and ducted ranges.

Before you scroll: exact meanings can vary between model series — treat this as a well-informed starting point, not a service manual for your specific unit. And if a code appears alongside burning smells, breaker trips or water pouring from the unit, skip the table: switch off and call 0434 951 341.

How to find your Mitsubishi Electric fault code

1

MSZ wall splits — count the indicator blinks

  1. 1 The wireless remote shows no code. When a fault trips, the indoor fan stops and the OPERATION INDICATOR lamp blinks in bursts.
  2. 2 Count the blinks between the 2.5-second pauses, and watch at least two full cycles to be sure of the count.
  3. 3 A continuous 0.5-second on/off blink with no pause means an indoor–outdoor signal fault.
  4. 4 On multi (MXZ) systems: if the lamp stays on for 3 seconds before the burst, the fault is in the outdoor unit; no 3-second lead-in means it's the indoor unit.
2

Wired controllers (ducted and optional on splits)

  1. 1 The check code appears directly on the controller screen.
  2. 2 Older PAR-21/PAR-31 controllers show two-character codes (P-codes indoor, E-codes communication, U/F-codes outdoor).
  3. 3 Newer PAR-40/41 backlit controllers, central controllers and MELCloud show 4-digit codes instead — the two systems map to each other (U2 = 1102, P5 = 2502).
3

Careful: recall mode uses a different table

  1. 1 These units memorise faults, and a technician can replay them using the failure-mode recall function.
  2. 2 The recall blink counts are NOT the same as the live blink counts — the same number means different things in each mode.
  3. 3 If a count doesn't match what you're seeing, check whether the unit is in normal operation or recall mode.
Worth knowing: Mitsubishi Electric and Mitsubishi Heavy Industries are different companies with completely different code systems — MHI's E-number codes do not apply to these units. Meanings also vary by series (MSZ-GE vs MSZ-AP recall tables differ, as do MXZ-2F vs MXZ-3F/4F outdoor tables), so confirm against the manual for your exact model — the model number is on a label under or beside the front panel.

Mitsubishi Electric fault code tables

Try this first safe check before calling anyone Book a service needs a technician Switch off & call stop running the system

MSZ wall splits (wireless remote) — operation indicator blink patterns

Code What it means Likely cause What to do
Continuous blink (0.5s on/off) Indoor unit is not receiving the serial signal from the outdoor unit (indoor–outdoor communication fault) Miswiring of the indoor–outdoor connecting cable, no power to the outdoor unit, tripped breaker, or interference on the signal line Try this first

Switch the system off at the isolator/breaker for 2 minutes, then restore power and retry; if the lamp resumes blinking, book a technician

2 blinks (then 2.5s off) Indoor coil thermistor or room temperature thermistor fault Sensor short or open circuit detected during operation Book a service
3 blinks Indoor fan motor fault — no speed feedback signal from the fan Fan motor failure, jammed line-flow fan, or indoor PCB fault Book a service
4 blinks Indoor control system fault Indoor electronic control PCB cannot read its nonvolatile memory — board failure Book a service
5 blinks Discharge temperature fault — the compressor discharge thermistor read above 116°C and the compressor stopped. It restarts once the discharge temperature falls to 100°C or less. Compressor or inverter fault, closed stop valve, or power supply problem Switch off & call
6 blinks Outdoor thermistor fault An outdoor sensor short or open circuit during compressor operation Book a service
7 blinks Heat sink or PCB over-temperature — the inverter fin thermistor exceeded roughly 75–86°C (varies by model series) and the unit shut down to protect the electronics. Inverter PCB or outdoor control PCB memory error Book a service
14+ blinks Other outdoor unit abnormality Closed stop valve, 4-way valve fault or other outdoor fault — a technician identifies the detail via the failure-mode recall function Book a service
Upper lamp lit + lower lamp blinking MXZ multi-split mode conflict — this indoor unit is asking for a different mode (COOL vs HEAT) than the unit that started first Indoor units on one MXZ outdoor unit set to opposing modes; the first unit running has priority Try this first

Set all indoor units on the multi system to the same mode (all cooling or all heating) — this is normal behaviour, not a fault

MXZ multi-split outdoor faults — indoor lamp flash counts (failure-mode recall, MXZ-F series)

Code What it means Likely cause What to do
2 flashes Outdoor power system fault — overcurrent protection tripped 3 times within a minute of compressor start Compressor wiring fault, inverter fault or closed stop valve Switch off & call
3 flashes Outdoor thermistor fault (discharge, defrost, ambient, fin, PCB or heat-exchanger sensor) Sensor short or open circuit while the compressor runs Book a service
4 flashes Compressor overcurrent — excessive current into the inverter power module Compressor winding fault, loose compressor connector or closed stop valve Switch off & call
5 flashes Discharge temperature too high (over ~115°C) Refrigerant shortage/leak or expansion valve (LEV) fault Switch off & call
6 flashes High-pressure protection — outdoor heat exchanger over 70°C in cooling (or indoor gas pipe in heating) Blocked outdoor coil, restricted airflow, closed stop valve or refrigerant circuit problem Try this first

With the unit off, clear leaves and debris from around the outdoor unit and clean the indoor filters; if it recurs, book a technician

7 flashes Inverter fin or PCB over-temperature (fin ~88–90°C) Blocked airflow around the outdoor unit, outdoor fan problem or sensor fault Try this first

Ensure the outdoor unit has clear airflow — remove debris and anything stacked around it — then power cycle; recurrence needs a technician

8 flashes Outdoor fan motor fault — failed 3 times within 30 seconds of starting Fan motor failure or obstruction in the fan Book a service
9 flashes Nonvolatile memory data cannot be read properly, OR a power module fault (short circuit in the power module output or compressor winding). Inverter or outdoor control PCB failure Book a service
10 flashes Low discharge temperature protection Refrigerant overcharge/circuit problem or expansion valve (LEV) fault Switch off & call
11 flashes The inverter's DC bus-bar voltage cannot be detected normally, or the compressor phase currents cannot be detected normally. Wiring between outdoor boards, power supply voltage problem or PCB failure Book a service
14–17 flashes (model-dependent) Refrigerant system abnormality — closed stop valve or air in the circuit detected (2F series); LEV/drain pump fault at 15 flashes on 3F/4F series Stop valve left closed after installation, gas leak, air trapped in the refrigerant circuit, or indoor LEV/drain pump fault Switch off & call

Wired controller check codes — indoor unit (P / E / F codes: ducted SEZ & PEA, any unit on a PAR controller)

Code What it means Likely cause What to do
E0 / E3 Remote controller transmission error Wiring/connection fault between controller and indoor unit, or wrong master/slave (grouping) settings Book a service
E1 / E2 Remote controller control board error Faulty wired controller board Book a service
E4 Remote controller signal receiving error Comms fault indoor unit → controller; addressing error on grouped/twinned systems Book a service
E5 Remote controller transmission error (controller not receiving reply from indoor unit) Controller wiring fault, wrong main/sub (master/slave) controller setting, duplicated addressing in grouped systems, or electrical interference Try this first
E6 / E7 Indoor/outdoor unit communication error Outdoor unit powered before indoor, electrical noise on S1/S2/S3 (classically a condensate pump wired into the terminals), loose connecting cable Try this first

Power the whole system off at the breaker for 2 minutes and restore — this clears most one-off interference trips; if E6/E7 returns, book a technician

E8 / E9 / EE Indoor–outdoor communication failure (transmitting error) S2/S3 signal wiring fault, units powered up in the wrong order, or interference from pumps wired into the terminals Try this first

Power cycle at the breaker for 2 minutes (this also re-sequences indoor-then-outdoor power-up); recurrence needs a technician

EA / Eb / EC Indoor–outdoor wiring and start-up faults: EA = miswiring (too many indoor units connected, 4 or more); Eb = miswiring (wires reversed or disconnected); EC = start-up time over (the indoor and outdoor units didn't finish their communication handshake in time — not a compressor fault). Wrong/loose inter-connecting cables, wrong cable size, noise interference; EC = unit failed to initialise after power-up Book a service
Ed Serial communication error between outdoor control board and inverter board Loose inter-board connectors, failed inverter or control PCB in the outdoor unit (4-digit equivalent: 0403) Book a service
F4 49C connector open (compressor discharge thermal protector circuit open) Discharge thermo protector tripped or its connector disconnected/broken on the outdoor board Book a service
Fb Indoor unit control system error Indoor PCB memory error or board failure Book a service
P1 Intake (return air) sensor error Room/return-air thermistor TH1 open or short circuit, or unplugged from the board Book a service
P2 / P9 Pipe (liquid or 2-phase pipe) sensor error Indoor coil thermistor TH2/TH5 open or short circuit Book a service
P4 Drain sensor error Drain float sensor open/short circuit or disconnected Book a service
P5 Drain pump error — high condensate level detected Drain pump failure or a blocked condensate drain line Try this first

Check the condensate drain outlet outside for kinks or blockage and clear any debris; if water has backed up or the code returns, book a technician

P6 Freezing (cooling) / overheating (heating) safeguard operation on the indoor coil Reduced airflow — dirty filters, blocked return air, fan problem — or a refrigerant charge issue Try this first

Clean the return-air filters, make sure all supply/return grilles are open, then power cycle for 2 minutes; recurrence needs a technician

P8 Pipe temperature error — no temperature change detected at the indoor coil during operation Most commonly refrigerant leakage; can also be a mis-mounted thermistor or the outdoor unit having tripped Switch off & call
PA Forced compressor stop due to a water leakage abnormality. Compressor protection triggered (e.g. water leak / abnormal condition detected) Switch off & call
PL Refrigerant circuit abnormal Leak, blockage or valve problem in the refrigerant circuit Switch off & call
Pb (PB) Indoor unit fan motor error Indoor fan motor or motor drive circuit failure, jammed blower wheel, or loose fan motor connector — very common on ducted SEZ/PEAD units Book a service
UE Abnormal high pressure — stop/ball valve closed Service valves left closed after installation or service, or a blockage in the refrigerant circuit Book a service
UL Abnormal low pressure Refrigerant undercharge/leak, closed valve, or low-pressure sensor fault Book a service

Wired controller check codes — outdoor unit (U / F codes)

Code What it means Likely cause What to do
F1 / F2 / F7 Power phase fault (reverse phase or missing L3 phase) — three-phase ducted systems Phases connected in the wrong order or an open phase in the supply; possible board fault Switch off & call
F3 / F5 / F9 Protection device circuit open (63L low-pressure switch, 63H high-pressure switch, or two or more devices) Pressure switch disconnection or contact failure; possible outdoor board fault Book a service
U1 / Ud Abnormal high pressure (63H switch operated) or overheating safeguard Outdoor fan failure, blocked/dirty outdoor coil, system blockage, or blocked indoor filters when heating Try this first

Turn the unit off, clear leaves/debris around the outdoor unit, clean indoor filters, then power cycle; if it trips again, book a technician

U2 Abnormally high discharge temperature, the compressor thermal protector (49C) has operated, or the system is low on refrigerant. Insufficient refrigerant (leak), faulty thermistor or extreme operating conditions Switch off & call
U3 Discharge thermistor fault Sensor open/short circuit or disconnected Book a service
U4 Outdoor unit thermistor fault An outdoor sensor open/short circuit or disconnected Book a service
U5 Abnormal inverter heat-sink temperature Lack of airflow around the outdoor unit/heat sink, or a faulty sensor Try this first

With power off, clear anything blocking airflow around the outdoor unit, then power cycle; recurrence needs a technician

U6 Compressor overcurrent / power module abnormality Compressor electrical fault or inverter power module failure Switch off & call
U7 Superheat abnormality due to low discharge temperature Refrigerant overcharge, expansion valve (LEV) fault or faulty discharge thermistor Book a service
U8 Outdoor unit fan safeguard stop Fan motor fault or fan obstructed Try this first

With power off at the breaker, check nothing (leaves, sticks, ice) is fouling the outdoor fan and clear debris; if the fan still won't run, book a technician

U9 / UH Over/under-voltage, abnormal synchronous signal to main circuit, or current sensor error Power supply voltage problem, wiring fault or inverter board failure Switch off & call
UF Compressor overcurrent interruption — compressor locked Seized/locked compressor Switch off & call
UP Compressor overcurrent interruption Compressor drawing excessive current — electrical or mechanical compressor fault Switch off & call

4-digit check codes (newer PAR-40/41 controllers, MELCloud & central controllers)

Code What it means Likely cause What to do
0403 Serial communication error (outdoor control board to inverter board) Board-to-board wiring/connector fault or failed inverter/control PCB — one of the most common outdoor PCB faults technicians see Book a service
1102 High compressor discharge temperature (equivalent to U2) Refrigerant shortage or discharge thermistor fault Switch off & call
1301 Abnormal low pressure detected before/at startup Refrigerant leak or shortage, closed service valve, or pressure sensor fault Book a service
1302 High pressure fault (equivalent to U1) Blocked outdoor coil, fan failure, closed valve or system blockage Try this first

Clear debris around the outdoor unit and clean indoor filters, then power cycle for 2 minutes; if it recurs, book a technician

1500 / 1501 Refrigerant charge abnormality — 1500 overcharge, 1501 shortage (low discharge superheat / compressor shell temperature) Incorrect charge at installation or a refrigerant leak — the classic 'low on gas' fault customers ask about Book a service
2500 Water leakage / drain sensor submergence detected (drain fault while unit is stopped) Blocked condensate drain or failed drain pump letting water rise in the tray — risk of ceiling water damage on ducted units Switch off & call
2502 Drain pump fault — water detected in the drip tray (equivalent to P5) Drain pump failure or blocked condensate drain Try this first

Check the condensate drain outlet for blockage and clear it; if water remains or the code returns, book a technician

2503 Drain sensor fault (equivalent to P4) Drain float sensor open/short circuit Book a service
4102 / 4115 Power supply abnormal — open phase or supply fault Loss of a phase, blown fuse, wiring or PCB problem Switch off & call
4116 Fan motor abnormal Indoor fan motor or board fault Book a service
4220 Abnormal bus voltage in the inverter Mains supply voltage problem or inverter board fault Switch off & call
4230 Heatsink (inverter) overheat protection Blocked outdoor coil, failed outdoor fan, or debris restricting airflow over the inverter heatsink — clear leaves/debris and restore clearance first Try this first
4240 Overload (compressor overheat) protection activated Dirty coils/filters, over- or under-charge, or high ambient causing sustained compressor overload Book a service
4250 Overcurrent protection — inverter power module or compressor (equivalent to U6/UF) Compressor lock or inverter IPM failure Switch off & call
4255 Fan motor abnormality (fan RPM error) Failed DC fan motor or fan drive circuit, seized bearing, or obstructed fan — a frequent 'outdoor fan not spinning' complaint Book a service
5101 – 5105 Thermistor faults at indoor/outdoor unit (5104 discharge = U3, 5105 outdoor = U4) A temperature sensor open/short circuit or disconnected from the board Book a service
5110 Heatsink temperature thermistor (THHS) fault Open/short circuit in the inverter heatsink sensor or its connector on the outdoor board Book a service
5201 / 5202 High-pressure (63H) / low-pressure (63L) switch circuit open (equivalent to F5/F3) Pressure switch disconnection or contact failure Book a service
5300 / 5301 Current sensor (ACCT) error Open/short circuit in the compressor current sensor or inverter board fault; can also flag when the compressor draws no current (wiring/compressor fault) Book a service
5701 Drain float switch fault (loose connector or float switch tripped) Condensate safety float switch activated by rising water, or its connector loose on the indoor board — seen on ducted units with safety trays Book a service
6201 / 6202 Remote controller board fault (6201 flash memory error, 6202 clock IC error) Failed PAR wired controller internal board — replace the controller Book a service
6600 Duplicate address (address overlap) on the communication line Two units or controllers set to the same address after installation or board replacement — readdress and reset power Book a service
6607 / 6608 Communication error — no acknowledgement/response on the transmission line Transient noise interference, wiring fault or loss of transmission voltage Try this first

Power the outdoor unit off for 30 seconds to 2 minutes and restore power; if the code returns, book a technician

6831 – 6834 MA remote controller communication fault Controller wiring on TB15 loose, cable run too long, too many controllers, or noise interference Book a service
6840 / 6841 / 6844 / 6845 / 6846 Indoor–outdoor communication/wiring faults (equivalent to E8/E9/EA/EB/EC) Miswired or loose connecting cables, wrong cable spec, power-up sequence, or start-up time-out Try this first

Power cycle the whole system at the breaker for 2 minutes; persistent codes mean a wiring fault that needs a technician

Reference compiled from Mitsubishi Electric service and operation documentation. Codes and meanings are provided as general guidance for the Australian residential range and can differ between model series; no affiliation with Mitsubishi Electric is implied.

Found your code?

Tell us the code when you book — diagnosis starts before we arrive

Air conditioning service and repairs across Perth from $220 inc GST — all brands, splits and ducted. Quoting the fault code gives us a head start on where to look; we then test and confirm the actual fault on site before any part is ordered, so you never pay for a part you didn't need.

Frequently Asked Questions

How do I read the blinking light on my Mitsubishi Electric split?

Count the blinks of the operation indicator between the 2.5-second pauses, watching at least two full cycles to be sure. A continuous blink with no pause means an indoor–outdoor signal fault. On multi (MXZ) systems, a 3-second lit period before the burst means the fault is in the outdoor unit.

Is this the same as Mitsubishi Heavy Industries?

No. Mitsubishi Electric and Mitsubishi Heavy Industries are different companies with different code systems — MHI's E-number codes don't apply to these units and vice versa. Check the badge on your indoor unit before using either table.

What's the difference between the 2-character and 4-digit codes?

They're the same faults in two conventions: older PAR-21/PAR-31 controllers show codes like U2 or P5, while newer PAR-40/41 controllers, central controllers and MELCloud show 4-digit equivalents (U2 = 1102, P5 = 2502). Both tables are on this page.

My blink count doesn't match anything in the table — why?

Almost certainly because the unit is in failure-mode recall rather than live operation — the two modes use different blink numbering. Series also differ (MSZ-GE vs MSZ-AP, MXZ-2F vs MXZ-3F/4F). Call 0434 951 341 with your model number and the count and we'll decode it.