Perth's Midea fault code lookup

Midea fault codes decoded

71 codes covered — what each one means, the likely cause, and whether it's worth trying something yourself before booking. Compiled from Midea documentation.

FAST RESPONSE
Prompt & reliable
FREE QUOTES
No obligation
WA OWNED
Local family team
FULLY INSURED
Licensed & covered

Midea systems show their fault code directly in the indoor unit's display window — no button sequence needed. Midea has used two code generations: the older E/P/F codes and the newer EH/EL/EC/PC system, and both are covered below, along with the status codes (defrost, self-clean, Wi-Fi pairing) that look alarming but aren't faults at all.

Before you scroll: exact meanings can vary between model series — treat this as a well-informed starting point, not a service manual for your specific unit. And if a code appears alongside burning smells, breaker trips or water pouring from the unit, skip the table: switch off and call 0434 951 341.

How to find your Midea fault code

1

Wall splits — the code shows on the unit itself

  1. 1 No button sequence needed: the code appears in the indoor unit's display window (where the set temperature normally shows), either steadily or alternating with the temperature.
  2. 2 Codes start with E, P, F, or in the newer system EH / EL / EC / PC.
  3. 3 Midea's own advice: wait about 10 minutes (many protection codes self-clear), then switch off at the breaker, restore power and restart.
  4. 4 If the code comes back, note it down and book a technician rather than repeatedly resetting.
2

Units without a display — count the lamps

  1. 1 Count the Operation/Running lamp flashes in one burst, then look at what the Timer lamp is doing — it selects the code family.
  2. 2 Timer lamp OFF = an E/EH/EL/EC-type error (2 flashes = communication error, 6 = indoor sensors, 8 = refrigerant leak detection, 12 = outdoor fan).
  3. 3 Timer lamp ON = an older-style F-code (1 flash = overcurrent, 6 = outdoor fan).
  4. 4 Timer lamp FLASHING = a P/PC protection code (1 = overcurrent, 2 = voltage, 3 = overheat/pressure, 7 = IPM).
3

Ducted systems & outdoor units

  1. 1 Ducted and any unit on a KJR-series wired controller show the code directly on the controller screen, using the same table as wall splits.
  2. 2 Multi-split outdoor units have their own display showing codes plus status readouts (dF = defrosting, PH = pre-heat, LP = low ambient) — those status codes are not faults.
  3. 3 Single-split outdoor units signal via LED combinations on the board behind the service cover — technician territory.
Worth knowing: Midea changed code systems between generations — old E0/E1/F4 map to new EH 00/EL 01/EC 51, and in the new system H means indoor-side, C outdoor-side, E error and P protection. The same code can also mean different things on the indoor display versus the outdoor display (P1, P3 and P5 in particular). Always confirm against the manual for your exact model before ordering parts.

Midea fault code tables

Try this first safe check before calling anyone Book a service needs a technician Switch off & call stop running the system

E-codes — indoor unit faults (older display style: most wall splits, multi-split indoor units, ducted/cassette)

Code What it means Likely cause What to do
AP Wi-Fi/WLAN pairing (access-point) mode is active. Not a fault. Smart-kit pairing triggered, often by pressing the LED/DO NOT DISTURB button 7 times; exits by itself or after pairing completes. Try this first
CL Filter-clean reminder on most models (Active Clean / self-clean running on some newer ranges). Not a fault. Accumulated run-hours trigger the reminder; or the self-clean cycle is running (20–30 min). Try this first
CP Unit switched off by the (wired) remote controller. Not a fault. Remote-off state; turn the unit back on from the controlling remote. Try this first
E0 (also EA) Indoor unit EEPROM (memory chip) parameter error — the indoor control board has lost or corrupted its settings Control board memory glitch after a power spike or brown-out; failed indoor main PCB Try this first

Switch off at the isolator/breaker for 2 minutes and restart; if E0 returns, book a technician — the indoor board usually needs replacing

E1 Indoor and outdoor units have stopped talking to each other (communication error) Loose or damaged interconnect wiring between the units, wiring not to the diagram, electrical interference, or a failed indoor/outdoor board Try this first

Power cycle at the breaker for 2 minutes; if E1 comes straight back, book a service call — the interconnect wiring must be checked by a licensed tech

E2 Zero-crossing signal detection error — the indoor board can't read the mains AC waveform properly Unstable power supply or a faulty indoor control board Book a service
E3 Indoor fan speed is out of control (running outside its normal range) Fan obstructed or airflow choked by dirty filters, failed indoor fan motor, or fan-drive fault on the PCB Try this first

Turn the unit off, clean the return-air filters and check nothing is fouling the fan barrel, then restart; if the code persists the fan motor needs a technician

E4 Indoor room temperature sensor (T1) is open-circuit or short-circuited Unplugged, damaged or failed room air sensor, or corroded connector Book a service
E5 Indoor evaporator coil temperature sensor (T2) is open-circuit or short-circuited Failed or dislodged coil sensor, or damaged sensor lead Book a service
E7 Outdoor fan speed out of control on most models; on some models a communication error between the outdoor main chip and compressor-drive chip, or display-board fault (model-dependent). Seized/obstructed outdoor fan, failed outdoor fan motor or its driver, or outdoor PCB fault. Book a service
EC Refrigerant leak detected — the system senses it is losing gas Refrigerant leak at a flare joint, coil or pipework; system undercharged Switch off & call
EE Water level alarm — condensate is not draining (ducted and cassette units with a drain pump) Blocked condensate drain, failed drain pump, or stuck float switch Try this first

Switch the unit off and check the condensate drain outlet isn't kinked or blocked; if water has built up or the code returns, book a technician before water damage occurs

Eb (new system: EH 0b) Communication error between the indoor main board and the display board. Loose or damaged display-board ribbon/connector, or a faulty indoor main board. (E6 is a different fault: on outdoor displays it's PFC module protection; on older R/9V/9A-series units it's a room or coil sensor fault.) Book a service
dF Defrost in progress — the outdoor unit is melting ice off its coil in heating mode. Indoor fan pauses and steam may rise from the outdoor unit. Not a fault; the single most common 'code' customers report in winter. Normal defrost cycle in cold/humid weather. Only a concern if it repeats constantly or heating never resumes (then possible refrigerant or sensor issue). Try this first

F-codes — outdoor-side faults shown on the indoor display (older style)

Code What it means Likely cause What to do
F0 Overload/over-current protection — the system is drawing too much current Overcharged or restricted refrigerant circuit, failing compressor, low voltage, or blocked condenser Switch off & call
F1 Outdoor ambient temperature sensor (T4) is open-circuit or short-circuited Failed or disconnected outdoor air sensor Book a service
F2 Outdoor condenser coil temperature sensor (T3) is open-circuit or short-circuited Failed or disconnected condenser coil sensor Book a service
F3 Compressor discharge temperature sensor (T5/TP) is open-circuit or short-circuited Failed or disconnected discharge-line sensor Book a service
F4 Outdoor unit EEPROM (memory) parameter error Outdoor control board memory corruption or board failure Book a service
F5 Outdoor fan speed is out of control (DC fan motor) Fan blade jammed by leaves/debris, failed outdoor fan motor, or fan-drive fault Try this first

With the unit switched off, clear leaves, grass and debris from around the outdoor unit and check the fan spins freely; if the code returns, book a technician

F6 Evaporator coil outlet sensor (T2B) open-circuit or short-circuited (multi-split indoor units) Failed or disconnected T2B sensor on that indoor unit Book a service
F7 / F8 / F9 Motorised front (lifting) panel faults on premium wall splits: F7 panel communication error, F8 panel mechanical/electrical malfunction, F9 panel not returned to closed position. Panel obstruction, panel motor/limit-switch failure, or panel-controller wiring fault. Book a service
FA Communication fault between the two chips on the indoor board (A6 ducted units) Indoor control board fault Book a service
FC / SC FC = forced-cooling (commissioning/test) mode; SC = self-clean cycle running. Neither is a fault. FC is entered via the unit's manual button during service/commissioning — power-cycle to exit. SC runs 20–30 min after the clean function is selected. Try this first
FL 09 Indoor and outdoor units are mismatched (incompatible model pairing detected). Wrong indoor/outdoor combination installed, or capacity/dip-switch configuration error at installation. Book a service
FP Frost-protection / 8°C heating mode is active — the unit is deliberately holding the room above ~8°C. Not a fault. 8°C mode enabled on the remote/app (often accidentally). Try this first

P-codes — protection shutdowns (older style; treat as serious)

Code What it means Likely cause What to do
P0 IPM power module fault or IGBT over-current protection — the inverter power stage has tripped Failed inverter module, compressor fault, or supply problem Switch off & call
P1 Over-voltage or under-voltage protection — the supply voltage is outside the unit's safe range. On the outdoor display of some larger multi-split units, P1 instead means high-pressure protection. Grid voltage sag/surge, poor connections, or a failing outdoor board Switch off & call
P2 High-temperature protection of compressor top or IPM module (high pressure on some models) Blocked condenser airflow, refrigerant issue, or failing compressor Switch off & call
P3 On the indoor display of a multi-split: low outdoor ambient temperature protection. Shown on the outdoor unit's own display, P3 instead means compressor over-current protection. Outdoor temperature below the unit's operating limit; not a component failure Try this first

No action needed — the unit resumes when the outdoor temperature rises; only book service if it shows in mild weather

P4 Inverter compressor drive error — the outdoor board can't drive the compressor properly Compressor winding fault, failed inverter drive board, or wiring fault Switch off & call
P5 On a multi-split outdoor display: condenser high-temperature protection. On some older residential series, P5 instead means inverter module protection. Condenser coil clogged with dirt/debris, airflow blocked, or very hot install location Try this first

Switch off and clear debris, plants and rubbish from around the outdoor unit so air can flow; if it trips again, book a technician

P6 Low-pressure protection — refrigerant pressure has dropped too low Refrigerant leak or undercharge, or a failed pressure switch Switch off & call

EH / EL codes — indoor unit faults (new code system: Xtreme, INFINI, All Easy Pro/AP and current ranges)

Code What it means Likely cause What to do
EH 00 / EH 0A Indoor unit EEPROM parameter error (new-system equivalent of E0) Indoor control board memory corruption or board failure Try this first

Power cycle at the breaker for 2 minutes; if it returns, book a technician

EH 0E Water-level alarm malfunction — condensate is not draining (tank full, or the water-level float switch signal is abnormal). New-system counterpart of the old EE code, mostly on ducted/cassette and any unit with a condensate pump. Blocked or kinked drain line, failed condensate/drain pump, stuck or faulty float switch, unit not level, or float-switch wiring/PCB fault. Book a service
EH 0b Communication error between indoor main board and display board Loose display cable or faulty PCB Book a service
EH 02 Zero-crossing signal detection error Unstable power supply or faulty indoor board Book a service
EH 03 Indoor fan speed operating outside the normal range Dirty filters restricting airflow, obstructed fan barrel, or failing indoor fan motor Try this first

Clean the return-air filters and check the fan barrel is clear, then restart; book service if the code returns

EH 60 Indoor room temperature sensor (T1) open-circuit or short-circuited Failed or disconnected room sensor Book a service
EH 61 Evaporator coil temperature sensor (T2) open-circuit or short-circuited Failed or dislodged coil sensor Book a service
EH 62 / EH 65 Additional evaporator coil temperature sensor faults: EH 62 = T2B sensor, EH 65 = T2A sensor, short or open circuit (larger ducted/air-handler indoor units). Failed or unplugged coil sensor, damaged sensor lead, or indoor PCB fault. Book a service
EH b3 Communication error between the wired wall controller and the indoor unit (mainly ducted/cassette with wired controllers). Loose or damaged controller cable, wrong controller wiring, or failed controller/indoor PCB. Book a service
EL 0C Refrigerant leak detected (new-system equivalent of EC) Refrigerant leak or severe undercharge Switch off & call
EL 01 Indoor/outdoor unit communication error (new-system equivalent of E1) Interconnect wiring fault, interference, or a failed control board Try this first

Power cycle at the breaker for 2 minutes; persistent EL 01 needs a licensed technician to check the interconnect wiring

EL 11 / EL 16 EL 11 = communication error between master and slave indoor units (twinned ducted systems); EL 16 = communication error between adapter board and outdoor main board. Inter-unit/adapter wiring fault, addressing error, or failed comms/adapter board. Book a service
FH 0d Ionizer (air-purifier module) malfunction Failed ionizer module; cooling/heating usually still works Book a service

EC codes — outdoor-side faults shown on the indoor display (new code system)

Code What it means Likely cause What to do
EC 0d Outdoor unit malfunction detected by the indoor unit — a generic flag that the outdoor unit has logged its own fault. Any outdoor-side protection or fault; the specific code must be read at the outdoor unit's PCB display/LEDs. Book a service
EC 07 Outdoor fan speed operating outside the normal range (new-system equivalent of F5) Fan jammed by debris, failed outdoor DC fan motor, or drive fault Try this first

With power off, clear debris around the outdoor unit and check the fan spins freely; book service if the code returns

EC 50 Outdoor temperature sensor fault — one of T3/T4/T5 open or shorted (multi-split outdoor display) Failed outdoor sensor or connector Book a service
EC 51 Outdoor unit EEPROM parameter error (new-system equivalent of F4) Outdoor control board memory corruption or board failure Book a service
EC 52 Outdoor condenser coil sensor (T3) open-circuit or short-circuited Failed or disconnected condenser coil sensor Book a service
EC 53 Outdoor ambient temperature sensor (T4) open-circuit or short-circuited Failed or disconnected outdoor air sensor Book a service
EC 54 Compressor discharge temperature sensor (TP/T5) open-circuit or short-circuited Failed or disconnected discharge sensor Book a service
EC 55 Outdoor IPM (inverter power module) temperature sensor fault — short or open circuit. Failed IPM temperature sensor, loose connector, or outdoor inverter board fault. Book a service
EC 56 Evaporator coil outlet sensor (T2B) open-circuit or short-circuited (multi-split indoor units) Failed or disconnected T2B sensor Book a service
EC 71 Over-current failure of the outdoor DC fan motor Seized or failing outdoor fan motor Book a service
EC 72 Missing-phase failure of the outdoor DC fan motor Fan motor winding or connector fault Book a service

PC codes — protection shutdowns (new code system; mostly multi-split/ducted outdoor units)

Code What it means Likely cause What to do
PC 00 IPM power module fault or IGBT over-current protection (equivalent of P0) Failed inverter module or compressor fault Switch off & call
PC 0A High-temperature protection of the condenser coil Outdoor coil clogged or airflow blocked Try this first

Switch off and clear debris and vegetation from around the outdoor unit; if it trips again, book a technician

PC 0F PFC (power factor correction) module protection Outdoor power-electronics fault or supply problem Switch off & call
PC 0L (or LP) Low outdoor ambient temperature protection — too cold outside to run safely Outdoor temperature below operating limit; not a component failure Try this first

Wait for the outdoor temperature to rise — the unit resumes automatically; book service only if it appears in mild weather

PC 01 Over-voltage or under-voltage protection — DC bus voltage out of range (equivalent of P1) Mains voltage problem or failing outdoor board Switch off & call
PC 02 High-temperature protection of compressor top or IPM module, or high-pressure protection (equivalent of P2) Blocked condenser, refrigerant problem, or failing compressor Switch off & call
PC 03 Low-pressure protection — refrigerant pressure too low Refrigerant leak or undercharge Switch off & call
PC 04 Inverter compressor drive error (equivalent of P4) Compressor or inverter drive board failure, or wiring fault Switch off & call
PC 06 Compressor discharge temperature protection — the compressor is running too hot Low refrigerant, blocked circuit, or failing compressor Switch off & call
PC 08 Current overload protection (equivalent of F0) System overdrawing current — refrigerant, compressor or electrical fault Switch off & call
PC 10 / PC 11 / PC 12 Outdoor voltage protections — low AC supply voltage (PC 10) or DC bus over-voltage / MCE drive error (PC 11/12) Supply voltage problems or outdoor main board failure Switch off & call
PC 30 / PC 31 High-pressure (PC 30) or low-pressure (PC 31) protection on larger multi-split outdoor units Refrigerant charge fault, blocked coil, or failed pressure switch Switch off & call
PC 40 Communication fault between the outdoor main chip and the compressor-drive (IPM) chip Outdoor board fault or board-to-board wiring Book a service
PC 43 / PC 44 / PC 45 / PC 46 / PC 49 Compressor drive failures — missing phase (43), zero-speed (44), IR chip drive (45), speed out of control (46), compressor over-current (49) Compressor winding, wiring, or inverter drive board failure Switch off & call

Reference compiled from Midea service and operation documentation. Codes and meanings are provided as general guidance for the Australian residential range and can differ between model series; no affiliation with Midea is implied.

Found your code?

Tell us the code when you book — diagnosis starts before we arrive

Air conditioning service and repairs across Perth from $220 inc GST — all brands, splits and ducted. Quoting the fault code gives us a head start on where to look; we then test and confirm the actual fault on site before any part is ordered, so you never pay for a part you didn't need.

Frequently Asked Questions

Where does my Midea show its fault code?

In the display window on the indoor unit — the same window that shows the set temperature. The code either sits there steadily or alternates with the temperature. Units without a display signal via the Operation and Timer lamps instead; the flash-counting method is above the tables.

My Midea shows dF / CL / FP — is something wrong?

No. Those are status readouts, not faults: dF means the outdoor unit is defrosting (normal in cold-weather heating), CL is a filter-clean reminder, and FP means frost-protection heating is holding the room at about 8°C. They're listed in the status section on this page so you can stop worrying about them.

Why do the same codes mean different things on my outdoor unit?

Because Midea's indoor and outdoor displays use overlapping code letters for different faults — P1, P3 and P5 in particular mean one thing on the indoor display and something else on the outdoor one. Our tables note which display each meaning belongs to.

What are the EH, EL and EC codes?

They're Midea's newer code system, used on current ranges like Xtreme Save. The letter after E tells you where: H = indoor side, L = other/system, C = outdoor side. Old codes map across (E0 → EH 00, E1 → EL 01, F4 → EC 51), and both generations are in the tables here.