Perth's ActronAir fault code lookup

ActronAir fault codes decoded

293 codes covered — what each one means, the likely cause, and whether it's worth trying something yourself before booking. Compiled from ActronAir documentation.

FAST RESPONSE
Prompt & reliable
FREE QUOTES
No obligation
WA OWNED
Local family team
FULLY INSURED
Licensed & covered

ActronAir is the trickiest brand to look up, because the same E-number means different things on different equipment — E9 alone has four meanings across their ranges. The tables below are split by controller and product family, so find your system first (the model number is on the outdoor unit's rating plate), then read the code in that section.

Before you scroll: exact meanings can vary between model series — treat this as a well-informed starting point, not a service manual for your specific unit. And if a code appears alongside burning smells, breaker trips or water pouring from the unit, skip the table: switch off and call 0434 951 341.

How to find your ActronAir fault code

1

Ducted with an LM7 / LM24 wall controller

  1. 1 Nothing to press — the controller displays “EXX” on its screen when a fault is stored.
  2. 2 Note the digits after the E. That's your code.
  3. 3 Some protections show as flashing icons rather than codes: COOL + LOW flashing for 30 seconds is anti-freeze protection, HEAT + HIGH flashing is overheat protection, and HEAT flashing every 8 seconds is a normal defrost cycle.
  4. 4 A flashing FILTER light is a run-hours reminder, not a fault — clean the return-air filter, then press ON/OFF to clear it.
2

Ducted with an LR7 / NEO controller

  1. 1 The fault code (E01 through E104) appears directly on the controller screen.
  2. 2 At power-up each controller briefly shows its ID — C-1 is the master, C-2 and C-3 are secondary.
  3. 3 E56 on a secondary controller means it has lost contact with the C-1 master.
3

QUE touchscreen — the code is hidden

  1. 1 The home screen only shows an icon: a Failure icon means a fault is stored, a Warning icon means something needs attention, and Filter Clean is just the filter reminder.
  2. 2 The actual E-number lives in Menu > Technical, which ActronAir reserves for service technicians.
  3. 3 Menu > Dashboards is safe to look at and shows live status of the major components.
4

Wall splits — read the unit, not the remote

  1. 1 The remote never shows fault codes. The code appears in the small display window on the indoor unit (e.g. E4, F3, P1, or EH03 / EC51 on R-32 models).
  2. 2 If the display is hidden, count the OPERATION lamp flashes and check the TIMER lamp: TIMER off = E-family (indoor), TIMER on = F-family (outdoor), TIMER flashing = P-family (protection).
  3. 3 “dF” means defrosting and “CL” means the Active Clean cycle is running — neither is a fault.
Worth knowing: ActronAir E-numbers are NOT universal — the same number means different things across their ranges. E9, for example, is a pressure or phase error on a Classic/ESP Digital system, a low-pressure trip on an Advance/Aires, a comms fault on a WC-02 controller, and a twin-system indoor fault on a Cascade wall split. Match your equipment family (check the model number on the outdoor unit's rating plate) to the right table below before acting on any code. ActronAir also warns that a fault may not display on the wall controller until it has occurred several times, so an intermittent problem can be running long before you see a code. Technical support: 1800 119 229.

ActronAir fault code tables

Try this first safe check before calling anyone Book a service needs a technician Switch off & call stop running the system

ESP Platinum ducted (CRV / ERV / ARV / FRV / ERM) — LM7, LM24 and LM-ZC wall controllers

Code What it means Likely cause What to do
E3 Room temperature sensor fault (open or short circuit). Failed room sensor in the wall controller or a zone sensor, or a damaged/loose sensor cable. Book a service
E4 Indoor coil inlet sensor fault (open or short circuit). Failed coil-in thermistor on the indoor fan coil, or its plug has worked loose at the indoor board. Book a service
E5 Communication error between the outdoor and indoor units. Damaged or loose control wiring between the units, water ingress at a junction, or a failed board. Often transient after a storm or power event. Try this first

Switch the system off at the wall controller, then turn off both the indoor and outdoor isolators/breakers for 2 minutes, restore power and restart. If E5 comes back, book a technician.

E6 High discharge temperature — compressor discharge exceeded 138 °C. Almost always low refrigerant charge (a leak), a restriction in the refrigerant circuit, or a badly blocked outdoor coil. Switch off & call
E7 Outdoor coil sensor fault (open or short circuit). Failed or disconnected outdoor coil thermistor. Defrost control is unreliable while this is present. Book a service
E8 Outdoor discharge sensor fault (open or short circuit). Failed or disconnected discharge-line thermistor on the compressor. Book a service
E9 Low pressure (LP) switch has tripped. Loss of refrigerant, a blocked/iced indoor coil from a dirty return-air filter, or a stuck expansion device. Book a service
E10 Low pressure sensor fault (open or short circuit). Failed LP transducer or its wiring loom in the outdoor unit. Book a service
E11 High pressure (HP) switch has tripped. Restricted airflow across the outdoor coil — dirty coil, plants/debris/fence too close, recirculating hot air — or a failed condenser fan. Try this first

With the system off, clear leaves, grass clippings, plants and stored items from around and above the outdoor unit (allow clear space on all sides), gently hose loose debris off the outside of the coil fins, and clean the return-air filter. Then power cycle and restart.

E12 High pressure sensor fault (open or short circuit). Failed HP transducer or its wiring in the outdoor unit. Book a service
E14 Condenser pressure low. Low refrigerant charge, or operation in very low ambient conditions with a fan/control fault. Book a service
E15 Communication error with the variable speed drive (VSD). Loss of the internal data link between the outdoor control board and the inverter drive — loose plug, damaged loom, or failed drive. Book a service
E17 Peripherals error. An outdoor board peripheral device has failed self-check. Book a service
E18 Suction temperature sensor in the EEV module is open circuit. Failed or unplugged suction thermistor on the electronic expansion valve module. Book a service
E19 Suction temperature sensor in the EEV module is short circuit. Damaged suction thermistor or a chafed sensor cable. Book a service
E22 Ambient temperature sensor failure (open/short circuit) — unit drops to Safe Mode. Failed outdoor ambient thermistor. The unit keeps running on a fallback strategy with reduced efficiency. Book a service
E23 EEV board communication failure — unit drops to Safe Mode. Loss of comms to the electronic expansion valve board; loose plug or failed board. Book a service
E25 Ambient temperature not updated. The outdoor ambient reading has stopped refreshing — sensor or comms issue. Book a service
E26 Drive over current. The inverter has drawn more current than allowed — compressor loading up, seized/stiff compressor, or drive fault. Switch off & call
E27 Drive over voltage. Incoming mains voltage too high, or a drive/DC-bus fault. Switch off & call
E28 VSD temperature high. The inverter drive is overheating — blocked outdoor airflow, failed drive cooling, or extreme ambient. Try this first

Switch off and clear anything restricting airflow to the outdoor unit (debris, plants, covers, stacked items). Let it cool for 30 minutes before restarting. If it returns, book a technician.

E29 Low supply voltage to the drive. Mains supply sagging, an undersized or damaged supply cable, or a loose electrical connection. Switch off & call
E30 Drive trip lock — the inverter has locked out after repeated trips. A repeating underlying drive or compressor fault has latched the drive off. Switch off & call
E31 Drive internal error. Internal self-check failure in the inverter drive. Switch off & call
E32 / E33 Envelope protection — HP/LP trip detected by the drive pressure sensors. The compressor was pushed outside its safe pressure envelope; commonly airflow restriction (indoor filter or outdoor coil) or refrigerant charge issues. Book a service
E34 Derating — high VSD temperature. The unit reduces capacity to protect the drive. Restricted outdoor airflow or very high ambient temperature. Try this first

Clear debris, plants and stored items from around the outdoor unit and make sure hot discharge air isn't recirculating back into it. This is a derate, not a shutdown — the system will still run, just at reduced capacity.

E35 Derating — low suction pressure. Restricted indoor airflow (dirty filter, too few zones open) or low refrigerant charge. Try this first

Clean the return-air filter and open more zones so the system has enough airflow. If the derate persists after a clean filter and 3+ zones open, book a technician.

E36 Derating — low condenser pressure. Very low ambient conditions or charge/control issue. Book a service
E37 Derating — high condenser pressure. Dirty or obstructed outdoor coil, failed condenser fan, or extreme ambient heat. Try this first

With the unit off, gently hose loose dirt off the outside of the outdoor coil fins and clear at least 300 mm of space around the unit.

E38 Derating — output power limit reached. The drive is capping output to stay within safe limits. Book a service
E39 Defrosting timed out. The outdoor coil did not clear ice within the allowed time — heavy icing, failed defrost sensor, or reversing valve issue. Book a service
E40 VSD restarting too frequently. The drive is repeatedly stopping and restarting due to an underlying protection trip. Book a service
E41 DC link voltage low. Supply problem or a failing DC bus / capacitor bank in the inverter drive. Switch off & call

ESP Platinum QUE ducted (CRQ / ERQ / ARV / FRQ) — QUE QT-1000 touchscreen (codes read in the Tech Menu)

Code What it means Likely cause What to do
E02 Indoor coil IN sensor error (open or short circuit). Failed coil-inlet thermistor on the indoor unit. Book a service
E03 Room sensor error (open or short circuit). Failed wall-controller or zone temperature sensor, or a damaged sensor cable. Book a service
E04 Indoor coil sensor error (coil-out on 3-phase, coil-in on single phase). Failed indoor coil thermistor or loose plug at the indoor board. Book a service
E05 Communication error between the outdoor unit and the indoor unit Break in the RS485/comms pair between outdoor and indoor units, water in a junction, loose terminal, blown indoor 24 V supply, or a failed indoor/outdoor board. The outdoor board shows E05 while the QUE Tech Menu logs the same fault as E51 — a common source of confusion. Book a service
E13 VSD HSP connector jumper pin missing, or other drive error. A jumper link on the drive has been left off after a service, or an unclassified inverter fault. Book a service
E42 Envelope protection — extremely low evaporating pressure. Severe indoor airflow restriction (blocked filter, too few zones open, iced coil) or low refrigerant charge. Book a service
E43 Envelope protection — high compression ratio. The compressor is being asked to work outside its safe pressure ratio; typically airflow or charge related. Book a service
E44 Envelope protection — high condensing pressure. Blocked or dirty outdoor coil, failed condenser fan, or recirculating hot air. Try this first

Switch off and clear leaves, grass and obstructions from around the outdoor unit, then gently hose the outside of the coil fins. Restart after 5 minutes.

E45 Envelope protection — low compression ratio. Compressor operating outside its envelope, often with a valve or charge fault. Book a service
E47 Compressor torque limit error. The compressor is drawing more torque than allowed — mechanical stiffness, liquid flood-back or a drive fault. Switch off & call
E50 Outdoor board configuration error. The outdoor control board is set for the wrong model, or a firmware/parameter fault after a board replacement. Book a service
E51 Communication error between outdoor and indoor units. Damaged or loose interconnect wiring, water in a junction, or a failed board. Often transient after a power event. Try this first

Turn the system off at the touchscreen, then off at both isolators/breakers for 2 minutes, restore power and restart. If E51 returns, book a technician.

E52 Communication error between the indoor unit and the master (QUE) controller. Loose or damaged controller cable, or the touchscreen has lost its data link. Try this first

Power cycle the system at the breaker for 2 minutes. If the touchscreen still won't talk to the unit, book a technician — don't unscrew the controller yourself.

E53 Communication error between the indoor board and the zone (VAV / 8-zone) module. Loose zone module cable or a failed zone module. Book a service
E55 Communication error between BMS and outdoor unit. Building management / external control link lost — only applies where a BMS is connected. Book a service
E56 No master wall controller detected. The C-1 master controller has lost power, been disconnected, or its cable has failed. Try this first

Power cycle at the breaker for 2 minutes. If the main controller screen is blank or the code stays, book a technician.

E99 Envelope protection (general). The compressor has been driven outside its safe operating envelope. Book a service

Advance & Aires ducted (CRV / EVV / EAA / EFV, CRS / EVA) and Classic 2 (CRA / CCA / EVA / EAA / EFA) — NEO, LR7-1 and LC7-2 controllers

Code What it means Likely cause What to do
E01 (or E1) Indoor fan RPM feedback error — the indoor fan isn't running at the speed the board asked for. Heavily blocked return-air filter or grille, most zones closed, a seized/failing indoor fan motor, or a fan control board fault. Try this first

Turn the system off, remove and clean (vacuum or wash and fully dry) the return-air filter, make sure the return-air grille isn't blocked by furniture, open several zones, then power cycle at the breaker for 2 minutes and restart.

E03 (or E3) Indoor room temperature sensor error (open or short circuit). Failed sensor in the wall controller or a zone sensor, or damaged sensor wiring. ActronAir's own FAQ describes E3 as a sensor fault. Book a service
E04 (or E4) Indoor coil IN temperature sensor error (open or short circuit). Failed coil-inlet thermistor or a plug that has vibrated loose at the indoor board. Book a service
E06 (or E6) High discharge temperature — compressor discharge exceeded 117 °C. Low refrigerant charge (leak), restriction in the refrigerant circuit, or severe condenser airflow restriction. Switch off & call
E07 (or E7) Outdoor coil temperature sensor error (open or short circuit). Failed or disconnected outdoor coil thermistor — defrost control becomes unreliable. Book a service
E08 (or E8) Discharge temperature sensor error (open or short circuit). Failed or disconnected compressor discharge thermistor. Book a service
E09 (or E9) Low pressure (LP) switch tripped. ActronAir's official FAQ describes E9 as a low-pressure fault. Refrigerant loss, an iced-up indoor coil caused by a dirty filter or closed zones, or a stuck expansion valve. Book a service
E10 Low pressure sensor error (open or short circuit). Failed LP transducer or damaged sensor loom in the outdoor unit. Book a service
E11 High pressure (HP) switch tripped. Blocked or filthy outdoor coil, plants/debris around the unit, hot air recirculating, or a dead condenser fan. Try this first

Switch off, clear at least 300 mm around the outdoor unit (leaves, grass, plants, bins), gently hose loose debris off the outside of the coil fins, then restart. Note ActronAir documentation says HP/LP faults may not display until they've occurred several times.

E12 High pressure sensor error (open or short circuit). Failed HP transducer or its wiring. Book a service
E13 VSD HSP connector jumper pin missing (R-410A Uno board), or other drive errors. Jumper link left off after service, or an unclassified inverter drive fault. Book a service
E15 Communication error between the outdoor unit and the variable speed drive (Modbus link lost). Loose or damaged data cable between outdoor board and inverter, or a failed drive. Book a service
E18 Suction temperature sensor error (open/short circuit or abnormal reading). Failed suction-line thermistor or a chafed sensor cable. Book a service
E22 Ambient temperature sensor error (open/short circuit). Failed outdoor ambient thermistor; the unit runs on a fallback control strategy. Book a service
E26 Drive supply over current / compressor effective value over current. Excessive current draw — stiff or failing compressor, or drive fault. Switch off & call
E27 Drive supply over voltage. Mains voltage too high or a drive/DC-bus fault. Switch off & call
E28 Drive (IPM module) temperature high. Inverter overheating — restricted outdoor airflow or failed drive cooling. Try this first

Switch off, clear anything restricting airflow around the outdoor unit and let it cool for 30 minutes before restarting.

E29 Drive low supply voltage. Sagging mains supply, undersized or damaged supply cable, or a loose terminal. Switch off & call
E30 Drive trip lock. The inverter has latched off after repeated protection trips. Switch off & call
E41 DC link voltage low. Supply fault or failing DC bus capacitors in the inverter. Switch off & call
E42 Envelope protection — extremely low evaporating pressure. Severe indoor airflow restriction or low refrigerant charge. Book a service
E43 Envelope protection — high compression ratio. Compressor working outside its safe pressure ratio. Book a service
E44 Envelope protection — high condensing pressure. Dirty/blocked outdoor coil or failed condenser fan. Try this first

Switch off and clear debris and plants from around the outdoor unit, then gently hose the outside of the coil fins.

E45 Envelope protection — low compression ratio. Compressor operating outside its envelope; often a valve or charge fault. Book a service
E47 Compressor torque limit error. Compressor drawing excessive torque — mechanical stiffness, liquid flood-back, or drive fault. Switch off & call
E50 Outdoor board configuration error. Board configured for the wrong model or a parameter fault after board replacement. Book a service
E51 Communication error between the outdoor and indoor units. Damaged or loose interconnecting control wiring, water ingress, or a failed board. Frequently transient after storms or power outages. Try this first

Switch off at the wall controller, then off at both isolators/breakers for 2 minutes, restore power and restart. If it returns, book a technician.

E52 Communication error between the indoor unit and the wall controller. Loose or damaged controller cable, or a failed controller. Try this first

Power cycle at the breaker for 2 minutes. If the controller screen stays blank or the code returns, book a technician.

E55 Communication error between BMS and outdoor unit. External building-management control link lost — only relevant where a BMS is fitted. Book a service
E56 No master wall controller detected. The C-1 master LR7/NEO controller has lost power or its cable connection. Secondary controllers (C-2, C-3) will show this if the master is disconnected. Try this first

Power cycle at the breaker for 2 minutes and check whether the main controller lights up. If it stays dead, book a technician.

Inverter drive (VSD) fault codes E60–E104 — Advance, Aires and QUE Platinum outdoor units

Code What it means Likely cause What to do
E60 Compressor phase over current / instant over current. Compressor drawing excessive current on one phase — winding, bearing or drive fault. Switch off & call
E61 Compressor loss of phase / output phase loss. An open compressor winding or a broken drive output connection. Switch off & call
E62 DC bus over voltage. Mains surge or a regenerative/braking fault in the drive. Switch off & call
E63 DC bus under voltage. Supply dip, failing rectifier or capacitor bank. Switch off & call
E64 Compressor loss of rotor (or, on some models, voltage input over high). The drive has lost track of the compressor rotor — stalled or seizing compressor. Switch off & call
E65 Compressor U-phase current sensor fault (or input phase loss). Failed current sensor on the drive board, or a lost incoming supply phase. Switch off & call
E66 AC voltage imbalance / AC input loss of phase. Unbalanced or missing incoming supply phase — a supply-side electrical problem. Switch off & call
E67 Inverter de-saturation (or compressor model configuration error). IGBT de-saturation event in the drive — a hard electrical fault. Switch off & call
E68 Compressor V-phase current sensor fault. Failed current sensing circuit on the drive board. Switch off & call
E69 PFC-IGBT over temperature. Power factor correction stage overheating — restricted drive cooling or high load. Book a service
E70 Lost rotor position. The drive can no longer determine compressor rotor position — stalling or a sensing fault. Switch off & call
E71 Motor temperature sensor / thermistor fault. Failed compressor motor thermistor or its wiring. Book a service
E72 Pre-charge relay open. The drive's soft-charge relay has failed to close — drive board fault. Switch off & call
E73 Compressor W-phase current sensor fault. Failed current sensing circuit on the drive board. Switch off & call
E74 IGBT over current / PFC module over current (choke wiring or failure). Short or over-current in the drive power stage or its choke wiring. Switch off & call
E75 Compressor phase current fold-back timeout. The drive has been limiting current for too long — sustained overload. Book a service
E76 Power module temperature fold-back timeout. The drive has been derating on temperature for too long — cooling restriction or high ambient. Try this first

Switch off and clear airflow obstructions around the outdoor unit, then let it cool 30 minutes before restarting.

E77 AC input current fold-back timeout. Prolonged supply-current limiting — supply or load problem. Book a service
E78 PFC-IGBT temperature low, or auto-config communication timeout. Temperature sensing fault on the PFC stage, or a drive configuration handshake failure. Book a service
E79 IPM de-saturation protection / compressor hardware over current. Severe over-current event in the inverter power module. Switch off & call
E80 Motor temperature high. Compressor motor running hot — overload, low charge, or restricted airflow. Switch off & call
E81 Drive board temperature high. Drive electronics overheating. Book a service
E82 Power module temperature high. Inverter power module overheating — cooling restriction or extreme ambient. Try this first

Switch off and clear anything blocking airflow around the outdoor unit; let it cool before restarting.

E83 PFC-IGBT temperature high. Power factor correction stage overheating. Book a service
E84 Internal drive communication lost between DSP and PFC. Internal drive data link failure. Book a service
E85 Internal drive communication lost between comms processor and DSP. Internal drive data link failure. Book a service
E86 Compressor phase current imbalance. Uneven current across compressor windings — a failing compressor or drive output stage. Switch off & call
E87 Three-phase PFC current imbalance. Unbalanced supply or a fault in the PFC stage. Switch off & call
E88 Drive micro-electronic or EEPROM fault. Corrupted drive memory or a failed microcontroller. Book a service
E89 Motor over speed. Compressor running beyond its commanded speed — control or sensing fault. Switch off & call
E90 Compressor model configuration error (or non-synchronism protection). Drive configured for the wrong compressor after a board or compressor replacement. Book a service
E91 Inverter temperature imbalance. Uneven temperature across the inverter power module — sensing or cooling fault. Book a service
E92 PFC temperature imbalance. Uneven temperature across the PFC stage. Book a service
E93 Motor temperature low. Compressor motor thermistor reading implausibly low — sensing fault. Book a service
E94 Drive board temperature low. Board temperature sensing fault, or genuine extreme cold. Book a service
E95 Power module temperature low or sensor open circuit. Failed temperature sensing circuit on the inverter power module. Book a service
E96 PFC-IGBT temperature low or PFC temperature sensing circuit fault. Failed temperature sensing on the PFC stage. Book a service
E97 Comms ADC failure / drive IC reset malfunction. Analog-to-digital converter or processor reset fault inside the drive. Book a service
E98 PFC / input current sensor fault. Failed current sensing circuit on the drive. Switch off & call
E99 Compressor overload (or other drive malfunction). The compressor has been driven beyond its rated load. Switch off & call
E100 PFC hardware over current / drive charging circuit malfunction. Hard over-current event or a failed soft-charge circuit in the drive. Switch off & call
E101 PFC software over current / PFC module instant over current. Over-current detected in the power factor correction stage. Switch off & call
E102 PFC over voltage (or, on Aires/19 kW+ models, DC fan motor 1 malfunction). Over-voltage in the PFC stage, or a failed outdoor DC fan motor depending on model. Switch off & call
E103 Power module temperature low / sensor open fault (or DC fan motor 2 malfunction). Temperature sensing fault on the power module, or a failed second outdoor fan motor depending on model. Book a service
E104 Drive fault limit lockout (or compressor model error). The drive has locked out after exceeding its allowed number of faults. Switch off & call

Classic ducted (SRE / SRA / SRG) and ESP Digital ducted (SRD / SRV) — LM7 and LM24 wall controllers

Code What it means Likely cause What to do
E2 Indoor coil-out sensor fault (open or short circuit). ESP Digital SRD/SRV only. Failed coil-outlet thermistor or a loose plug at the indoor board. Book a service
E3 Room sensor(s) fault (open or short circuit). Failed wall-controller or zone temperature sensor, or damaged sensor cable. Book a service
E4 Indoor coil-in sensor fault (open or short circuit). Failed coil-inlet thermistor or loose connection. Book a service
E5 Communication error between the outdoor and indoor units. Loose or damaged control wiring between units, water in a junction, or a board fault. Often transient after a power event. Try this first

Turn the system off, switch off both indoor and outdoor isolators/breakers for 2 minutes, restore power and restart. If E5 returns, book a technician.

E6 Discharge high temperature fault — ActronAir's own documentation notes this usually means the system is low on refrigerant. Refrigerant leak, restriction in the refrigerant circuit, or badly blocked condenser airflow. Switch off & call
E7 Outdoor coil sensor fault (open or short circuit). Failed or disconnected outdoor coil thermistor. Book a service
E8 Outdoor discharge sensor fault (open or short circuit). ESP Digital SRD/SRV. Failed or disconnected discharge-line thermistor. Book a service
E9 High or low pressure trip, or phase error (phase error applies to 3-phase models). High side: dirty/blocked outdoor coil or failed condenser fan. Low side: refrigerant loss or an iced indoor coil from a blocked filter. On 3-phase: a supply phase problem. Try this first

Switch off, clean the return-air filter, and clear debris, plants and stored items from around the outdoor unit. Restart after 5 minutes. If E9 comes back — or if you are on a 3-phase supply — switch off and book a technician. ActronAir notes E9 may not display until it has occurred several times.

COOL + LOW flashing 30 s Anti-freeze protection mode (low capacity mode) — not an E-code. The indoor coil is running too cold, usually from restricted airflow: dirty return-air filter, too few zones open, or crushed ductwork. Try this first

Clean the return-air filter and open more zones so the system has enough airflow through the indoor coil.

HEAT + HIGH flashing 30 s Overheat safety protection — not an E-code. Indoor coil overheating in heating mode, usually from restricted airflow (blocked filter, closed zones). Try this first

Clean the return-air filter, open more zones, and check return-air grilles aren't blocked by furniture.

HEAT flashing every 8 s Defrost cycle, or indoor coil pre-heat after defrost — normal operation, not a fault. Cold, damp weather causing ice on the outdoor coil. Steam or water from the outdoor unit during this is normal. Try this first

No action needed — the indoor fan stays off for a few minutes so cold air isn't blown into rooms. It will resume by itself.

Wall-hung splits — Aurora (SWB) and Serene (WRC / WRE): codes on the indoor unit display, read via LED flash counts

Code What it means Likely cause What to do
CP Remote On/Off terminal is open circuit — not a hardware fault. An external on/off input (BMS, key switch or link) has been removed or opened. Book a service
E0 Indoor unit EEPROM parameter error. Operation lamp flashes 1×, timer lamp off. Corrupted memory or a failed indoor control board. Book a service
E1 Communication error between the indoor and outdoor units. Operation lamp flashes 2×, timer lamp off. Damaged or loose interconnecting cable, water ingress at the outdoor terminal block, or a failed board. Try this first

Switch the unit off at the wall isolator/breaker for 2 minutes, then restore power and restart. If E1 returns, book a technician.

E3 Indoor fan speed out of control. Operation lamp flashes 4×, timer lamp off. Blocked filters or air path restricting the fan, or a failing indoor fan motor / control board. Try this first

Turn the unit off, open the front panel, slide out and clean both filters (vacuum or wash and dry fully), refit them, and make sure the indoor air inlet and outlet aren't blocked by curtains or furniture.

E4 Indoor room temperature sensor T1 open or short circuit. Operation lamp flashes 5×, timer lamp off. Failed room thermistor on the indoor unit. Book a service
E5 Evaporator coil temperature sensor T2 open or short circuit. Operation lamp flashes 6×, timer lamp off. Failed indoor coil thermistor or loose plug. Book a service
E7 Communication error between the display board and the main indoor PCB (Serene WRC/WRE). Loose ribbon cable behind the indoor display, or a failed display board. Book a service
E8 Communication error between master and slave indoor units (twin systems). Operation lamp flashes 9×. Loss of the link between paired indoor units. Book a service
E9 Another indoor unit malfunction (twin systems). Operation lamp flashes 10×. The partner indoor unit has faulted — check its own display for the real code. Book a service
EC Refrigerant leakage detected. Operation lamp flashes 7×, timer lamp off. The unit has detected a loss of refrigerant charge — a leak in the indoor coil, outdoor coil or pipework. Switch off & call
EE Water level alarm — condensate not draining (cassette/ducted-type indoor units). Blocked or kinked condensate drain, a failed condensate pump, or a stuck float switch. Try this first

Turn the unit off and check the outside end of the condensate drain pipe for blockage (leaves, dirt, insects) and that it isn't kinked or lifted. If it's clear, or you can't safely reach it, book a technician — leaving it risks water damage to ceilings.

F0 Overload / over current protection. Operation lamp flashes 1×, timer lamp on. Excessive current draw at the outdoor unit — compressor or electrical fault. Switch off & call
F1 Outdoor ambient temperature sensor T4 open or short circuit. Operation lamp flashes 2×, timer lamp on. Failed outdoor ambient thermistor. Book a service
F2 Condenser coil temperature sensor T3 open or short circuit. Operation lamp flashes 3×, timer lamp on. Failed outdoor coil thermistor. Book a service
F3 Compressor discharge temperature sensor T5 open or short circuit. Operation lamp flashes 4×, timer lamp on. Failed discharge-line thermistor. Book a service
F4 Outdoor unit EEPROM parameter error. Operation lamp flashes 5×, timer lamp on. Corrupted memory or a failed outdoor control board. Book a service
F5 Outdoor fan speed out of control. Operation lamp flashes 6×, timer lamp on. Obstruction fouling the outdoor fan, or a failing fan motor / control board. Try this first

Switch off at the isolator and check for leaves, twigs or debris caught in the outdoor fan guard, and that plants aren't touching the unit. Clear it, then restore power. If F5 returns, book a technician.

F6 Indoor coil outlet sensor T2B open or short circuit (free-match indoor units). Operation lamp flashes 7×, timer lamp on. Failed coil-outlet thermistor, typically located at the outdoor low-pressure valve. Book a service
P0 IPM (inverter power module) malfunction or IGBT over-current protection. Operation lamp flashes 1×. Inverter power stage fault or a compressor drawing excessive current. Switch off & call
P1 Over voltage or under voltage protection. Operation lamp flashes 2×. Mains supply outside the unit's acceptable range, or a supply cable/connection fault. Switch off & call
P2 Compressor top high-temperature protection (or IPM module high temperature). Operation lamp flashes 3×. Compressor overheating — low refrigerant charge, blocked condenser airflow, or a mechanical fault. Switch off & call
P4 Inverter compressor drive error. Operation lamp flashes 5×. The drive cannot control the compressor — drive or compressor failure. Switch off & call

R-32 wall splits and R-32 Ultra Slim split ducted (URC / CRC / LRC) — alphanumeric EH / EL / EC / PC codes

Code What it means Likely cause What to do
EC0D Outdoor unit malfunction (general). 14 flashes. A fault reported by the outdoor unit that isn't broken out into a specific code — check the outdoor board display. Book a service
EC07 Outdoor fan speed operating outside the normal range. 12 flashes. Debris fouling the outdoor fan, or a failing fan motor. Try this first

Switch off at the isolator, clear leaves, twigs and plant growth from the outdoor fan guard and around the unit, then restore power.

EC51 Outdoor unit EEPROM parameter error. 5 flashes, timer lamp on. Corrupted memory or a failed outdoor control board. Book a service
EC52 Condenser coil temperature sensor T3 open or short circuit. 5 flashes. Failed outdoor coil thermistor. Book a service
EC53 Outdoor ambient temperature sensor T4 open or short circuit. 5 flashes. Failed outdoor ambient thermistor. Book a service
EC54 Compressor discharge temperature sensor TP open or short circuit. 5 flashes. Failed discharge-line thermistor. Book a service
EC56 Evaporator coil outlet sensor T2B open or short circuit (free-match indoor units). 5 flashes. Failed coil-outlet thermistor. Book a service
EH00 / EH0A Indoor unit EEPROM parameter error. 1 flash, timer lamp off. Corrupted memory or a failed indoor control board. Book a service
EH0E Water-level alarm — condensate not draining. 13 flashes, timer lamp off. Blocked condensate drain, failed pump, or stuck float switch. Try this first

Turn the unit off and check the outside end of the drain pipe is clear and not kinked. If it's clear or unreachable, book a technician before water damages ceilings.

EH0b Communication error between the two indoor processors. 9 flashes, timer lamp off. Internal indoor board fault or loose display ribbon. Book a service
EH03 Indoor fan speed operating outside the normal range. 4 flashes, timer lamp off. Blocked filters or restricted air path, or a failing indoor fan motor. Try this first

Turn the unit off and clean the indoor filters, and clear anything blocking the air inlet and outlet. Restart after 5 minutes.

EH3A External fan DC bus voltage too low protection. 4 flashes. Supply or fan-module power fault. Book a service
EH3b External fan DC bus voltage too high fault. 4 flashes. Supply over-voltage or a fan-module power fault. Switch off & call
EH60 Indoor room temperature sensor T1 open or short circuit. 6 flashes, timer lamp off. Failed indoor room thermistor. Book a service
EH61 Evaporator coil temperature sensor T2 open or short circuit. 6 flashes, timer lamp off. Failed indoor coil thermistor or loose plug. Book a service
EHbA Communication fault between the external fan module and the indoor unit. Loose or damaged fan module data cable, or a failed module. Book a service
EL0C Refrigerant leakage detected. 8 flashes, timer lamp off. Loss of refrigerant charge. R-32 is a mildly flammable (A2L) refrigerant, so a suspected leak needs prompt professional attention. Switch off & call
EL01 Indoor / outdoor unit communication error. 2 flashes, timer lamp off. Loose or damaged interconnecting control wiring, or a failed board. Often transient after a power event. Try this first

Switch off at the breaker for 2 minutes, restore power and restart. If EL01 returns, book a technician.

PC00 IPM malfunction or IGBT over-current protection. 7 flashes. Inverter power module fault or excessive compressor current. Switch off & call
PC01 Over voltage or under voltage protection. 2 flashes. Mains supply outside the acceptable range, or a supply cable fault. Switch off & call
PC02 Compressor top high-temperature protection or IPM module high-temperature protection. 3 flashes. Compressor or inverter overheating — low charge, blocked condenser airflow, or mechanical fault. Switch off & call
PC03 High pressure or low pressure protection (some models). 7 flashes. High side: blocked/dirty outdoor coil or failed fan. Low side: refrigerant loss or iced indoor coil. Try this first

Switch off, clean the indoor filter and clear debris and plants from around the outdoor unit, then restart after 5 minutes. If it returns, book a technician.

PC04 Inverter compressor drive error. 5 flashes. The drive cannot control the compressor — drive or compressor failure. Switch off & call

Cascade and Ultra Slim outdoor units (URC / CRE / LRE / LRC) — codes on the outdoor control board

Code What it means Likely cause What to do
E1 Indoor / outdoor communication malfunction. Damaged or loose interconnecting control wiring, or a failed board. Try this first

Power cycle at the breaker for 2 minutes and restart. If it returns, book a technician.

F0 Outdoor over current protection. Excessive current draw at the outdoor unit — compressor or electrical fault. Switch off & call
F1 Ambient temperature sensor (T4) malfunction. Failed outdoor ambient thermistor. Book a service
F2 Outdoor heat-exchanger (condenser coil) temperature sensor T3 malfunction. Failed outdoor coil thermistor. Book a service
F3 Discharge temperature sensor (T5 / TP) malfunction. Failed compressor discharge thermistor. Book a service
F4 Outdoor EEPROM malfunction. Corrupted memory or failed outdoor control board. Book a service
F5 Outdoor fan speed malfunction. Debris fouling the outdoor fan, or a failing fan motor. Try this first

Switch off at the isolator, clear debris and plant growth from the fan guard and around the unit, then restore power.

J0 Evaporator (indoor coil) high temperature protection. Indoor coil overheating in heating mode — usually restricted indoor airflow. Try this first

Clean the return-air filter and clear anything blocking the indoor air inlet and outlet.

J1 Condenser (outdoor coil) high temperature protection. Dirty or obstructed outdoor coil, failed condenser fan, or recirculating hot air. Try this first

Switch off, clear debris and plants from around the outdoor unit and gently hose loose dirt off the outside of the coil fins.

J2 High discharge temperature protection. Low refrigerant charge, restriction in the circuit, or blocked condenser airflow. Switch off & call
J3 PFC (power factor correction) module protection. Fault in the drive's PFC stage. Switch off & call
J4 Communication error between the outdoor main board and the compressor drive / IPM board. Loose internal data cable or a failed board. Book a service
J5 High pressure protection. Blocked or filthy outdoor coil, failed condenser fan, or hot air recirculating around the unit. Try this first

Switch off, clear at least 300 mm around the outdoor unit and gently hose the outside of the coil fins, then restart after 5 minutes.

J6 Low pressure protection. Refrigerant loss, or an iced indoor coil caused by a blocked filter. Book a service
J8 AC power input voltage protection. Incoming mains voltage outside the unit's acceptable range. Switch off & call
LP Low ambient temperature protection. Outdoor temperature below the operating range — usually self-clearing. Try this first

No action needed in genuinely cold conditions; the unit resumes as ambient rises.

P0 IPM (inverter power module) protection. Inverter power stage fault or excessive compressor current. Switch off & call
P1 DC voltage too high / too low protection. Supply voltage outside range, or a DC bus fault in the drive. Switch off & call
P2 Compressor top temperature protection. Compressor overheating — low charge or blocked condenser airflow. Switch off & call
P3 Ultra-low ambient temperature protection. Outdoor temperature below the unit's operating range — usually self-clearing as it warms up. Try this first

No action needed if it's a very cold morning — the unit will resume once ambient rises. If it shows on a mild day, book a technician (likely a faulty ambient sensor).

P4 Compressor rotor position protection / inverter compressor drive error. The drive has lost control of the compressor — stalling or drive failure. Switch off & call
P6 Compressor voltage protection. Voltage supplied to the compressor outside safe limits. Switch off & call
P7 Outdoor IGBT temperature sensor (TH) faulty — open or short circuit. Failed IGBT temperature sensing circuit on the drive. Book a service

WC-02 wired controller (Cascade, Ultra Slim, cassette and ducted indoor units) — note this scheme differs from ducted E-codes

Code What it means Likely cause What to do
E0 Phase sequence error or phase malfunction. Incoming supply phases wired in the wrong order or a lost phase — an electrical supply fault. Switch off & call
E1 Communication malfunction between the indoor and outdoor units. Loose or damaged control wiring, or a failed board. Often transient after a power event. Try this first

Switch off at the breaker for 2 minutes, restore power and restart. If E1 returns, book a technician.

E2 T1 (room) sensor malfunction. Failed indoor room thermistor. Book a service
E3 T2A (indoor coil) sensor malfunction. Failed indoor coil thermistor or loose plug. Book a service
E4 T2B (indoor coil outlet) sensor malfunction. Failed coil-outlet thermistor. Book a service
E5 T3 or TP (outdoor coil / discharge) sensor malfunction. Failed outdoor coil or discharge thermistor. Book a service
E6 Zero-cross check malfunction. Mains zero-crossing detection failure on the indoor board — supply or board fault. Book a service
E7 Indoor EEPROM malfunction. Corrupted memory or failed indoor control board. Book a service
E8 Fan controller out of control. Blocked filters restricting the fan, or a failing indoor fan motor / control board. Try this first

Turn the unit off and clean the return-air filter, and clear anything blocking the air inlet and outlet. Restart after 5 minutes.

E9 Communication malfunction between the main PCB and the display board. Loose ribbon cable behind the display, or a failed display board. (Note: this is NOT the ducted 'low pressure' E9.) Book a service
EA Compressor overload (has occurred 4 times). The compressor has repeatedly tripped its overload — mechanical, charge or electrical fault. Switch off & call
EB IPM (inverter power module) malfunction. Inverter power stage fault. Switch off & call
EC Air-clean malfunction. Fault in the air purification/clean function or its sensing. Book a service
ED Outdoor malfunction protection. The outdoor unit has reported a fault — check the outdoor board display for the specific code. Book a service
EE Full-water malfunction — condensate water level alarm. Blocked condensate drain, failed pump, or stuck float switch. Try this first

Turn the unit off and check the outside end of the condensate drain pipe is clear and not kinked. If it's clear or you can't reach it safely, book a technician before water damages ceilings.

EF Other fault. An unclassified fault — the real code will be on the indoor unit's own display. Book a service
F0 Communication error between the wired controller and the indoor unit. Loose or damaged controller cable, or a failed controller. Try this first

Power cycle at the breaker for 2 minutes. If the controller stays blank or F0 returns, book a technician.

F1 Elevating fascia panel not closed (auto-lifting panel cassettes). The motorised panel is obstructed, out of alignment, or its motor has failed. Try this first

Check nothing is obstructing the panel and that it can close freely, then power cycle. If it still won't close, book a technician.

P0 Evaporator temperature protection. Indoor coil temperature outside safe limits — usually restricted indoor airflow. Try this first

Clean the return-air filter and clear anything blocking the indoor air inlet and outlet.

P1 Anti-cold-air or defrost mode active — normal operation, not a fault. Cold weather defrost cycle or cold-draught prevention. Try this first

No action needed — normal operation. The fan resumes once the cycle finishes.

P2 Condenser temperature protection. Outdoor coil too hot — dirty coil, blocked airflow or failed condenser fan. Try this first

Switch off, clear debris and plants from around the outdoor unit and gently hose the outside of the coil fins.

P3 Compressor temperature protection. Compressor overheating — low refrigerant, blocked condenser airflow, or mechanical fault. Switch off & call
P4 Discharge pipe temperature protection. Discharge line too hot — commonly low refrigerant charge or a circuit restriction. Switch off & call
P5 Discharge high pressure protection. Blocked/dirty outdoor coil, failed condenser fan, or overcharge. Try this first

Switch off, clear at least 300 mm around the outdoor unit and hose loose dirt off the coil fins, then restart after 5 minutes.

P6 Discharge low pressure protection. Refrigerant loss, or an iced indoor coil caused by a blocked filter. Book a service
P7 Over-voltage protection. Mains supply voltage too high. Switch off & call
P8 Compressor overload protection. The compressor has drawn excessive current — mechanical, charge or electrical fault. Switch off & call
PF Other fault — check the indoor or outdoor unit for the specific code. An unclassified fault reported to the controller. Book a service

Status displays that are NOT faults (outdoor 7-segment display and controllers)

Code What it means Likely cause What to do
boot Outdoor board booting — shown for 30 seconds at power-up on inverter units. Normal start-up sequence. On older Classic/ESP Digital boards you instead see the CPU version number, then 8, then the status digit. Try this first

No action needed. Allow 5 minutes before expecting the compressor to start — the system has built-in safety timers.

oFF / CooL / HEAt Unit off / cooling mode / heating mode. Flashing means starting or turning off. Normal operating status. Try this first

No action needed.

dEF, dEF1, dEF2, dEF3 Defrost active, or 1/2/3 minutes until defrost begins. Normal cold-weather operation. The indoor fan stops for a few minutes and steam or water from the outdoor unit is normal. Try this first

No action needed — heating resumes automatically within a few minutes.

oiLr Oil return operation. Normal periodic cycle to return compressor oil. Try this first

No action needed.

dr-1 / dr-2 / dr-3 Demand Response Management active: DRM1 = compressor off, DRM2 = limited to 50% of rated power, DRM3 = limited to 75%. Your electricity network or retailer has signalled a demand-response event, or a DRM device is wired in. Not a fault. Try this first

No action needed — capacity returns to normal when the event ends. If it's permanently in DRM, ask your installer to check the DRM wiring.

ohP / dtP / cPP / hSP Unit derating: overheat protection / discharge temperature protection / condenser pressure protection / high suction pressure protection. The unit is deliberately reducing capacity to protect itself, usually because of restricted airflow or extreme ambient conditions. Try this first

Clean the return-air filter, open more zones, and clear debris and plants from around the outdoor unit. If the system keeps derating in mild weather, book a technician.

dF / CL (wall splits) 'dF' = defrosting, 'CL' = Active Clean cycle running on the indoor unit. Normal operation. During Active Clean the unit runs 20–45 minutes then switches off automatically. Try this first

No action needed — let the cycle finish.

fC (wall splits) Forced cooling mode, entered from the MANUAL CONTROL button on the indoor unit. The manual control button has been pressed (used when the remote is lost or flat). Cycles forced AUTO (24.0) → forced COOL (fC) → OFF. Try this first

Press the MANUAL CONTROL button again to cycle back to OFF, then use the remote normally once you replace its batteries.

C-0 / C-1 / C-2 / C-3 (LR7) Wall controller address shown for 3 seconds at power-up. C-1 is the master. Normal power-up display. C-0 means no address assigned yet — if it never changes, the controller isn't talking to the indoor board. Try this first

If the display stays on C-0, power cycle at the breaker. If it still shows C-0, book a technician (likely a wiring or cable fault).

PAS / FAL (LR7 self-learn) Self-Learn commissioning routine passed (PAS) or failed (FAL) on Advance series EVV indoor units. Shown during installer commissioning of the auto fan mode. FAL usually means duct static is out of range or the filter/grille wasn't fitted. Book a service
FILTER light flashing Run-hours filter reminder on the wall controller — not a fault. The microprocessor has counted the preset number of run hours since the last reset. Try this first

Clean the return-air filter (vacuum or wash and dry fully — every 4 weeks is ActronAir's recommendation), refit it, then press ON/OFF to clear the filter light.

Outdoor unit LED indicators — single-phase soft starter (SS9 / SS1P) and Actron Connect Wi-Fi module

Code What it means Likely cause What to do
SS9 LED — on for 2–3 minutes at power-up Random power-up delay before a start is allowed. Normal anti-surge start delay. Try this first

No action needed — wait a few minutes for the compressor to be allowed to start.

SS9 LED — on for 2 min 50 s after the compressor stops Anti-cycle protection delay (a minimum 5 min 50 s start-to-start delay also applies). Normal compressor protection timer. Try this first

No action needed — this is why a system won't restart immediately after being switched off.

SS9 LED — 1 blink (resets after 5 min 50 s) High running current trip. Compressor drawing excessive current — mechanical stiffness, high head pressure, or supply problem. Switch off & call
SS9 LED — 2 blinks (resets after 5 min 50 s) Low running current trip. Compressor drawing abnormally low current — commonly loss of refrigerant charge or a failed compressor valve. Book a service
SS9 LED — 3 blinks (lock out) Locked start-capacitor fault. Failed start capacitor or its wiring. Five lockouts in a row latch the soft starter off until mains is cycled. Switch off & call
SS9 LED — 4 blinks (lock out) Locked rotor detected. The compressor is not turning — seized or mechanically jammed compressor, or a failed start component. Switch off & call
SS9 LED — 5 blinks (until voltage is corrected) Low mains voltage. Supply voltage below the acceptable range — network issue, undersized cable, or loose connection. Switch off & call
SS9 LED — 6 blinks (lock out) External run capacitor fault. Failed run capacitor or its wiring. Switch off & call
Actron Connect ACM-2 — RED LED Power indicator: on = powered, off = no power. Off means the module has lost supply — a tripped breaker, unplugged module, or failed power supply. Try this first

Check the system breaker/isolator is on and power cycle for 2 minutes. If the red LED stays off, book a technician.

Actron Connect ACM-2 — BLUE LED Wi-Fi status: solid on = connected; rapid flashing = connecting to network; slow pulse = access point (setup) mode; flashing = no connection. No connection usually means the router has changed channel/password, the signal is too weak, or the module needs re-pairing. Try this first

Restart your router, then power cycle the air conditioner at the breaker for 2 minutes and re-run the app's Wi-Fi setup. Note this only affects app control — the wall controller still runs the system normally.

Cascade split system (URC / CRE) — indoor unit display / LED flash counts (extend the existing Cascade group, which currently only covers the outdoor board)

Code What it means Likely cause What to do
F7 Communication error between the auto-lifting panel and the slim cassette, or auto-lifting panel faulty Loose/damaged ribbon or plug between the auto-lifting (motorised) front panel and the indoor PCB, or a failed panel motor/limit switch. Applies to slim cassette indoor units fitted with an auto-lifting panel. Book a service
F8 Auto-lifting panel is not closed The motorised filter/front panel has not returned to the fully closed position — commonly after cleaning the filters, or something is fouling the panel travel. Try this first
F9 IPM (inverter power module) malfunction Inverter power module fault in the outdoor unit — failed IPM/IGBT stage, compressor winding short, low supply voltage or loose DC bus/compressor terminations. Unit will normally lock out and stop. Switch off & call

Multi Split system (MRE / BRE indoor heads) — indoor unit display / LED flash counts (MISSING GROUP)

Code What it means Likely cause What to do
CP Unit switched off by the remote on/off switch (remote on/off terminal open circuit) External on/off or BMS contact is open, or the link/jumper across the remote on/off terminals has been removed or has come loose. Try this first
E0 Indoor unit EEPROM parameter error Corrupt or unreadable configuration memory on the indoor PCB, often after a supply surge or brownout. Book a service
E1 Communication malfunction between indoor and outdoor units Interconnect comms wiring open, shorted, reversed, or water-affected; wrong indoor address; failed indoor or outdoor PCB. One of the most common multi-head faults. Book a service
E3 Indoor fan speed malfunction (fan motor out of control) Blocked/dirty filter or coil stalling the fan, seized bearings, obstructed fan wheel, faulty DC fan motor or missing RPM feedback to the indoor PCB. Try this first
E4 Indoor room temperature sensor (T1) malfunction Open or short-circuit room sensor, or unplugged sensor at the indoor PCB. NOTE: on multi-split this is the ROOM sensor — on Aurora/Serene wall splits E4 is the evaporator coil sensor, so the code must not be shared with the wall-split table. Book a service
E5 Evaporator coil temperature sensor (T2) malfunction Open or short-circuit indoor coil sensor, or sensor dislodged from its coil pocket. Book a service
E7 Communication error between the indoor PCB and the display PCB Damaged or unseated display ribbon/plug, or a failed display board. Book a service
EE Water-level alarm malfunction (cassette and ducted indoor types only) Condensate tray full — blocked or kinked drain, failed condensate pump, faulty float switch, or drain line with insufficient fall. Classic 'unit stops and drips' complaint. Try this first
F1 Outdoor ambient temperature sensor (T4) malfunction Open or short-circuit outdoor ambient sensor, or damaged sensor lead at the outdoor PCB. Book a service
F2 Condenser coil temperature sensor (T3) malfunction Open or short-circuit outdoor coil sensor, or sensor fallen out of its coil clip (also causes poor defrost). Book a service
F3 Compressor discharge temperature sensor (T5) malfunction Open or short-circuit discharge sensor on the compressor discharge line, or unplugged at the outdoor PCB. Book a service
F4 Outdoor unit EEPROM parameter error Corrupt configuration memory on the outdoor PCB, typically after a supply disturbance. Book a service
F5 Outdoor fan speed malfunction Obstructed or seized outdoor fan, debris in the fan guard, failed DC fan motor or lost RPM feedback. Book a service
F6 Indoor coil outlet pipe sensor malfunction (sensor located on the outdoor unit low-pressure service valve) Open or short-circuit T2B pipe sensor at the outdoor manifold, or the sensor is not clamped to the correct branch pipe. Book a service
P0 Inverter module (IPM) malfunction Inverter power stage fault — failed IPM/IGBT, compressor winding short to earth, or loose DC bus/compressor terminations. Switch off & call
P1 Over-voltage or under-voltage protection Mains supply outside the drive's operating window — brownout, undersized or loose supply conductors, poor neutral, or a site-wide voltage problem. Switch off & call
P4 Compressor drive malfunction Inverter cannot start or control the compressor — lost rotor position, compressor mechanically stuck, or failed drive stage. Book a service
P5 Indoor unit mode conflict Two or more heads on the same outdoor unit have been set to opposing modes (e.g. one heating, one cooling). A multi-split can only run all heads in the same mode family at once — set all heads to the same mode or turn the conflicting head off. Try this first
P6 High or low pressure fault — read the MRC outdoor board code to identify which (J5 = high pressure protection, J6 = low pressure protection) High side: blocked outdoor coil, failed outdoor fan, recirculating hot air. Low side: refrigerant loss, blocked filter/indoor coil, restricted EEV or a closed service valve. Switch off & call

Multi Split outdoor unit (MRC) — codes on the outdoor control board (MISSING GROUP)

Code What it means Likely cause What to do
E0 Outdoor unit EEPROM parameter error Corrupt or unreadable configuration memory on the outdoor main PCB. Book a service
E2 Communication malfunction between indoor and outdoor units Interconnect comms pair open/shorted/reversed, water ingress at a joint, or a failed indoor or outdoor PCB. Book a service
E3 Communication malfunction between the IPM board and the outdoor main control board Damaged or unseated internal loom between the inverter (IPM) board and the main outdoor PCB, or a failed IPM board. Book a service
E4 Outdoor temperature sensor malfunction — coil sensor T3, ambient sensor T4, compressor discharge sensor T5 or indoor coil outlet pipe sensor T2B Any one of the outdoor thermistors open or short circuit, or unplugged. Each must be ohmed out individually to identify which. Book a service
E5 Over-voltage or under-voltage protection Supply voltage outside the permitted range at the outdoor unit — brownout, loose or undersized supply, or poor neutral connection. Switch off & call
E6 PFC (power factor correction) module protection PFC stage trip in the inverter — supply distortion/imbalance, choke wiring fault, or a failed PFC/IGBT stage. Book a service
E8 Outdoor fan speed malfunction Outdoor fan obstructed or seized, debris in the fan guard, failed DC fan motor or missing speed feedback. Book a service
F1 Indoor unit A coil outlet temperature sensor malfunction Open or short-circuit T2B sensor for branch A at the outdoor manifold, or sensor not clamped to the correct branch pipe. Book a service
F2 Indoor unit B coil outlet temperature sensor malfunction Open or short-circuit T2B sensor for branch B at the outdoor manifold. Book a service
F3 Indoor unit C coil outlet temperature sensor malfunction Open or short-circuit T2B sensor for branch C at the outdoor manifold. Book a service
F4 Indoor unit D coil outlet temperature sensor malfunction Open or short-circuit T2B sensor for branch D at the outdoor manifold. Book a service
F5 Indoor unit E coil outlet temperature sensor malfunction Open or short-circuit T2B sensor for branch E at the outdoor manifold. Book a service
P1 High pressure protection (MRC-100AS-4, MRC-110AS-5 and MRC-135AS-5 only) Blocked or dirty outdoor coil, failed outdoor fan, hot-air recirculation, overcharge, or a restriction on the discharge side. Switch off & call
P2 Low pressure protection (MRC-100AS-4, MRC-110AS-5 and MRC-135AS-5 only) Refrigerant loss/leak, closed or partly closed service valve, blocked indoor filter or coil, or a restricted EEV. Switch off & call
P3 Current overload protection Compressor drawing excessive current — high head pressure, tight/failing compressor, low supply voltage, or a failing run capacitor/drive stage. Switch off & call
P4 Compressor discharge temperature protection Discharge temperature above limit — low refrigerant charge, restricted EEV, non-condensables, or a stuck reversing valve. Book a service
P5 Condenser high temperature protection Outdoor coil temperature above limit — dirty coil, obstructed airflow around the unit, failed outdoor fan, or hot-air recirculation in a tight enclosure. Try this first
P6 Inverter module (IPM) protection Inverter power stage trip — over-current, failed IPM/IGBT, compressor winding fault, or loose DC bus/compressor terminations. Switch off & call

Reference compiled from ActronAir service and operation documentation. Codes and meanings are provided as general guidance for the Australian residential range and can differ between model series; no affiliation with ActronAir is implied.

Found your code?

Tell us the code when you book — diagnosis starts before we arrive

Fault finding across Perth from $165 inc GST — all brands, splits and ducted. Quoting the fault code gives us a head start on where to look; we then test and confirm the actual fault on site before any part is ordered, so you never pay for a part you didn't need.

Frequently Asked Questions

Why does the same ActronAir code mean different things?

Because ActronAir has built several generations of controller — LM7/LM24, LR7/NEO, QUE touchscreen, the WC-02 and the wall-split boards — and each has its own code table. E9 is a pressure or phase error on a Classic, a low-pressure trip on an Advance, a comms fault on a WC-02 and a twin-system indoor fault on a Cascade. Always match the table to your equipment before acting.

My QUE screen shows a Failure icon but no code — where's the code?

QUE keeps the E-number in Menu > Technical, which ActronAir reserves for service technicians. The home screen only shows the icon. Menu > Dashboards is safe to browse and shows live component status, which is often enough to describe the problem over the phone.

The FILTER light is flashing — is that a fault?

No. That's a run-hours reminder. Clean the return-air filter, then press ON/OFF to clear it. Similarly, HEAT flashing every 8 seconds is a normal defrost cycle, not a fault.

My system played up but the controller shows nothing — why?

ActronAir's own documentation notes that a fault may not display on the wall controller until it has occurred several times. Intermittent faults can run for weeks before a code appears, which is why a system that misbehaves without a code still deserves a look.